![](/images/graphics-bg.png)
Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads
Joint Authors
Elias, Said
Rupakhety, R.
Olafsson, S.
Source
Issue
Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-13, 13 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2019-11-19
Country of Publication
Egypt
No. of Pages
13
Main Subjects
Abstract EN
This study presents analysis of a benchmark building installed with tuned mass dampers (TMDs) while subjected to wind and earthquake loads.
Different TMD schemes are applied to reduce dynamic responses of the building under wind and earthquakes.
The coupled equations of motion are formulated and solved using numerical methods.
The uncontrolled building (NC) and the controlled building are subjected to a set of 100 earthquake ground motions and wind forces.
The effectiveness of using different multiple TMD (MTMD) schemes as opposed to single TMD (STMD) is presented.
Optimal TMD parameters and their location are investigated.
For a tall structure like the one studied here, TMDs are found to be more effective in controlling acceleration response than displacement, when subjected to wind forces.
It is observed that MTMDs with equal stiffness in each of the TMDs (usually considered for wind response control), when optimized for a given structure, are effective in controlling acceleration response under both wind and earthquake forces.
However, if the device is designed with equal mass in every floor, it is less effective in controlling wind-induced floor acceleration.
Therefore, when it comes to multihazard response control, distributed TMDs with equal stiffnesses should be preferred over those with equal masses.
American Psychological Association (APA)
Elias, Said& Rupakhety, R.& Olafsson, S.. 2019. Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads. Shock and Vibration،Vol. 2019, no. 2019, pp.1-13.
https://search.emarefa.net/detail/BIM-1211484
Modern Language Association (MLA)
Elias, Said…[et al.]. Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads. Shock and Vibration No. 2019 (2019), pp.1-13.
https://search.emarefa.net/detail/BIM-1211484
American Medical Association (AMA)
Elias, Said& Rupakhety, R.& Olafsson, S.. Analysis of a Benchmark Building Installed with Tuned Mass Dampers under Wind and Earthquake Loads. Shock and Vibration. 2019. Vol. 2019, no. 2019, pp.1-13.
https://search.emarefa.net/detail/BIM-1211484
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID