Accuracy of endoscopic ultrasound guided fine needle aspiration biopsy in diagnosis of mediastinal and pancreatic pathology at King Hussein Medical Centre 2003-2006

Other Title(s)

دقة الخزعة الإرتشافية بالإبرة الدقيقة الموجهة بالإيكو عبر التنظير في تشخيص آفات العقد اللمفاوية المنصفية و الآفات البنكرياسية في مدينة الحسين الطبية في الأردن بين عامي 2003-2006

Author

al-Zubaydi, Ali Muthanna

Source

Journal of the Arab Board of Health Specializations

Issue

Vol. 11, Issue 2 (30 Jun. 2010), pp.9-17, 9 p.

Publisher

The Arab Board of Health Specializations

Publication Date

2010-06-30

Country of Publication

Syria

No. of Pages

9

Main Subjects

Medicine

Topics

Abstract AR

هدف البحث : تقييم حساسية، نوعية و دقة الخزعة الارتشافية بالإبرة الدقيقة الموجهة بالإيكو عبر التنظير (EUS-FNAB) في تشخيص آفات العقد اللمفاوية المنصفية، الآفات داخل البطن و الآفات البنكرياسية. طرق البحث : تم إجراء هذه التقنية عند 64 مريضا لديهم آفات في العقد المنصفية أو آفات داخل البطن أو آفات بنكرياسية و ذلك في مشفى مدينة الحسين الطبية في الفترة بين آذار 2003 و نيسان لعام 2006.

شمل البحث 25 مريضا يعانون من آفات في العقد المنصفية، 37 مريضا لآفات بنكرياسية و مريضين لآفات في العقد اللمفاوية داخل البطن.

تراوحت أعمار المرضى بين 40 و 70 سنة بينما توزعوا تبعا للجنس فكان 40 منهم من الرجال و 24 نساء.

تم استبعاد 5 مرضى من الدراسة : 4 رجال و امرأة واحدة و ذلك لعدم كفاية العينة المأخوذة و جميعهم كانوا لعينات بنكرياسية.

تم إجراء هذه الدراسة للحصول على التشخيص الأولي، أما التشخيص النهائي للحالة فقد اعتمد على المتابعة السريرية، الفحص الخلوي و / أو النتائج الجراحية. النتائج : لوحظ أن الخزعة الارتشافية بالإبرة الدقيقة الموجهة بالإيكو عبر التنظير ذات حساسية و نوعية عالية كأداة تشخيصية أولية في آفات العقد المنصفية، كما أن لها دورا في تمييز الآفات السليمة عن الخبيثة بحيث بلغت مجمل دقتها 91.5%، حساسيتها 85.3% و نوعيتها 100%.

أما بالنسبة لنمط الآفة، فقد بلغت قيم الحساسية، النوعية، الدقة، القيمة التنبؤية السلبية، القيمة التنبؤية الإيجابية 92.8%، 100%، 96%، 91.6% و 100% على الترتيب بالنسبةل آفات العقد اللمفاوية المنصفية، بينما بلغت هذه القيم 80%، 100%، 88%، 77.7% و 100% للآفات البنكرياسية على الترتيب.

تم الوصول لتشخيص أولي للخباثة باستخدام هذه التقنية في 49% من الحالات (29 من أصل 59 مريضا) المشتبه بها سريريا.

لوحظ أن دقة و حساسية هذه التقنية أقل في الآفات البنكرياسية بالمقارنة مع آفات العقد اللمفاوية.

لم يلاحظ تطور أية اختلاطات لهذه التقنية في هذه الدراسة ربما لصغر حجم العينة المدروسة. الاستنتاجات : تمثل الخزعة الإرتشافية بالإبرة الدقيقة الموجهة بالإيكو عبر التنظير (EUS-FNAB) إجراء آمنا، قليل الغزو، قادرا على توفير عينات نسيجية كافية للفحص و التشخيص الخلوي المرضي، كما أن هذه التقنية تعطي تشخيصا دقيقا لآفات المنصف، سرطان البنكرياس، كما أنها تفيد في التمييز بين الآفات السليمة و الخبيثة.

Abstract EN

Objective: To evaluate the sensitivity, specificity and accuracy of endoscopic ultrasonography guided fine-needle aspiration biopsy (EUS-FNAB) of lymph nodes in mediastinal, intra abdominal and pancreatic lesions. Methods: Sixty-four consecutive patients with mediastinal lymphadenopathy, pancreatic lesions and intra abdominal lymphadenopathy were examined by EUS+FNA at King Hussein Medical Centre, Amman, Jordan between March 2003 and April 2006.

Twenty five patients were examined for mediastinal lymph nodes, 37 for pancreatic lesions and two for abdominal lymph nodes.

Our patients were 40 men and 24 women with average age between 40 and 70 year.

Five patients were excluded from the study; 4 men and 1 woman because of inadequate sample all of them from pancreatic lesion.

The study was performed to obtain primary diagnosis, final diagnosis was based on clinical follow up, cytology and/or surgical results. Results: The endoscopic ultrasound guided fine needle aspiration biopsy of mediastinal nodal and pancreatic lesions were highly sensitive and specific as primary diagnosis procedures, and to differentiate between benign and malignant lesions with overall accuracy of 91.5%, sensitivity of 85.3% and 100% specificity.

Regarding the lesion type; the sensitivity, specificity, accuracy, negative predictive value and positive predictive value were 92.8%, 100%, 96%, 91.6% and 100% for mediastinal lymph node; 80%, 100%, 88%, 77.7% and 100% for pancreatic lesion respectively.

Primary diagnosis of malignancy was obtained by endoscopic ultrasound guided fine-needle aspiration biopsy in 49% (29/59) of patients with clinically suspicious lesion.

The accuracy and sensitively for pancreatic lesion is lower than that for lymph node.

No complications were reported in our study (this could be due to small sample size). Conclusions: Endoscopic Ultrasound Guided Fine-Needle Aspiration Biopsy (EUS-FNAB) is safe, minimally invasive and can readily obtain adequate tissue specimens for cytopathological diagnosis, moreover it provides accurate diagnosis of mediastinum, pancreatic cancer and differentiate malignant from benign lesions.

American Psychological Association (APA)

al-Zubaydi, Ali Muthanna. 2010. Accuracy of endoscopic ultrasound guided fine needle aspiration biopsy in diagnosis of mediastinal and pancreatic pathology at King Hussein Medical Centre 2003-2006. Journal of the Arab Board of Health Specializations،Vol. 11, no. 2, pp.9-17.
https://search.emarefa.net/detail/BIM-133880

Modern Language Association (MLA)

al-Zubaydi, Ali Muthanna. Accuracy of endoscopic ultrasound guided fine needle aspiration biopsy in diagnosis of mediastinal and pancreatic pathology at King Hussein Medical Centre 2003-2006. Journal of the Arab Board of Health Specializations Vol. 11, no. 2 (Jun. 2010), pp.9-17.
https://search.emarefa.net/detail/BIM-133880

American Medical Association (AMA)

al-Zubaydi, Ali Muthanna. Accuracy of endoscopic ultrasound guided fine needle aspiration biopsy in diagnosis of mediastinal and pancreatic pathology at King Hussein Medical Centre 2003-2006. Journal of the Arab Board of Health Specializations. 2010. Vol. 11, no. 2, pp.9-17.
https://search.emarefa.net/detail/BIM-133880

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 16-17.

Record ID

BIM-133880