Comparison between the diagnostic values of serum inflammatory markers, Interleukin-6 and C-reactive protein in detection the severity of acute appendicitis

Other Title(s)

مقارنة بين التشخيصية للمشعرات المصلية الإلتهابية (الإنترلوكين-6 و البروتين التفاعلي C )‎ في تحديد شدة إلتهاب الزائدة الحاد

Joint Authors

al-Shahwani, Imad Wajih
Kamal, Zuhayr Bashir
Hindush, Layth Nayif

Source

Journal of the Arab Board of Health Specializations

Issue

Vol. 11, Issue 2 (30 Jun. 2010), pp.36-44, 9 p.

Publisher

The Arab Board of Health Specializations

Publication Date

2010-06-30

Country of Publication

Syria

No. of Pages

9

Main Subjects

Medicine

Topics

Abstract AR

هدف البحث: يهدف هذا البحث إلى مقارنة القيمة التشخيصية للمشعرات الالتهابية: البروتين التفاعلي C و الإنترلوكين 6- (IL-6) في تحديد شدة التهاب الزائدة الحاد.

طرق البحث: تم إجراء دراسة مستقبلية امتدت من شهر كانون الأول 2008 و حتى شهر آذار لعام 2009 حيث شملت المرضى الذين خضعوا لعملية استئصال زائدة في قسم الجراحة في مشفى الكندي التعليمي في بغداد.

تم الحصول على عينات مصلية قبل الجراحة لتقييم مستويات البروتين التفاعلي C و الإنترلوكين 6-.

و بناء على الدلائل العيانية الملاحظة خلال الجراحة و الفحص النسيجي للعينات المستأصلة تم تقسيم المرضى إلى ثلاث مجموعات : المجموعة الأولى: حالة عدم وجود التهاب في الزائدة (أي الزائدة طبيعية(، المجموعة الثانية: حالة التهاب زائدة حاد غير مختلط (التهاب نزلي، قيحي(، و المجموعة الثالثة: حالة التهاب زائدة حاد مع اختلاطات (تنخر أو انثقاب).

تم إجراء ربط إحصائي بين القيم الملاحظة مخبريا للمشعرات الالتهابية و بين النتائج الملاحظة نسيجيا.

النتائج : شملت هذه الدراسة 50 مريضا، 28 ذكور (56 %) و 22 إناث (44 %)، بمتوسط أعمار 23 سنة (تراوح بين 50-7 سنة).

من خلال الفحص العياني خلال الجراحة و الفحص النسيجي للعينات المستأصلة فقد توضع 7 مرضى في المجموعة الأولى (14 %)، و 29 في المجموعة الثانية (58 %)، و 14 في المجموعة الثالثة (28 %).

أعطت نتائج الإنترلوكين 6- و البروتين التفاعلي C نتائج سلبية حقيقية في 6 % و 10 % على الترتيب، بينما أعطت نتائج إيجابية حقيقية في 82 % و 32 % على الترتيب، و نتائج سلبية كاذبة في 4 % و 54 % على الترتيب، و نتائج إيجابية كاذبة في 8 % و 4 % على الترتيب.

و من هنا يمكن من خلال هذه الدراسة القول بأن حساسية، نوعية، و دقة القيم المصلية للإنترلوكين 6- هي 95.34 %، 42.85 % و 88 % على الترتيب، أما بالنسبة للبروتين التفاعلي C فإنها 37.20 %، 77.42 % و 62 % على الترتيب.

الاستنتاجات : يجب التعامل مع النتائج المخبرية بشكل متآزر مع التقييم السريري.

يمكن لقيم البروتين التفاعلي C و الإنترلوكين -6- عند استخدامهما بشكل مدروس–أن تعطي الجراحين معلومات متتمة إضافية تفيد في تحديد مدى الحاجة لإجراء جراحة عاجلة.

Abstract EN

Objective: The aim of this study was to compare the diagnostic values of serum inflammatory markers, C-reactive protein (CRP) and interleukin-6 (IL-6) in detection the severity of acute appendicitis. Methods: This is a prospective study from December 2008 to March 2009 included all patients who had appendectomy in Department of Surgery, Al-Kindy Teaching Hospital - Baghdad/Iraq.

Serum for estimating levels of C-reactive protein (CRP) and interleukin-6 (IL-6) was taken pre-operatively.

Depending on the macroscopic evidence during the operation and the histopathological examination of the specimens, the patients were separated into 3 groups, group one with negative appendectomy (normal appendix), group two with non-complicated acute appendicitis (catarrhal, suppurative), and group three with complicated acute appendicitis (perforated, gangrenous).

The histopathological results were correlated with CRP and IL-6 values statistically. Results: A total number of 50 patients were included in this study, 28 males (56%) and 22 females (44%).

The mean age was 23 years (ranged from 7 to 50).

On the macroscopic evidence during the operation and the histopathological examination of the specimen, there were 7 patients (14%) in group one, 29 patients (58%) in group two, and 14 patients (28%) in group three.

Serum IL-6 and CRP values gave true negative results in 6% and 10% respectively, true positive results in 82% and 32% respectively, false negative results in 4% and 54% respectively, and false positive results in 8% and 4% respectively.

Therefore, in the present study the sensitivity, specificity, and accuracy of serum IL-6 were calculated as 95.34%, 42.85%, and 88% respectively, and the sensitivity, specificity, and accuracy of CRP values were calculated as 37.20%, 77.42%, and 62% respectively. Conclusions: Laboratory results should be considered to be integrated within the clinical assessment.

If used critically, CRP and IL-6 can provide surgeons with complementary information in discerning the necessity for urgent operation.

American Psychological Association (APA)

al-Shahwani, Imad Wajih& Kamal, Zuhayr Bashir& Hindush, Layth Nayif. 2010. Comparison between the diagnostic values of serum inflammatory markers, Interleukin-6 and C-reactive protein in detection the severity of acute appendicitis. Journal of the Arab Board of Health Specializations،Vol. 11, no. 2, pp.36-44.
https://search.emarefa.net/detail/BIM-134102

Modern Language Association (MLA)

al-Shahwani, Imad Wajih…[et al.]. Comparison between the diagnostic values of serum inflammatory markers, Interleukin-6 and C-reactive protein in detection the severity of acute appendicitis. Journal of the Arab Board of Health Specializations Vol. 11, no. 2 (Jun. 2010), pp.36-44.
https://search.emarefa.net/detail/BIM-134102

American Medical Association (AMA)

al-Shahwani, Imad Wajih& Kamal, Zuhayr Bashir& Hindush, Layth Nayif. Comparison between the diagnostic values of serum inflammatory markers, Interleukin-6 and C-reactive protein in detection the severity of acute appendicitis. Journal of the Arab Board of Health Specializations. 2010. Vol. 11, no. 2, pp.36-44.
https://search.emarefa.net/detail/BIM-134102

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 43-44.

Record ID

BIM-134102