Performance improvement of pv panel using water cooling technology under Egyptian conditions
Joint Authors
Khalil, A.
Abd al-Qayid, Muhammad
Hamdi, Muhammad
Source
Journal of Engineering Research
Issue
Vol. 2019, Issue 3، ج. 2 (30 Jun. 2019), pp.42-47, 6 p.
Publisher
Tanta University Faculty of Engineering
Publication Date
2019-06-30
Country of Publication
Egypt
No. of Pages
6
Main Subjects
Topics
Abstract EN
This paper presented the effect of water cooling technique on the performance of PV panels under Egyptian condition.
In this study three different positions of the cooling technique was studied (front side, backside and both sides simultaneously).
The results of this study was compared to the conventional PV model without cooling to obtain the optimal technology of cooling system.
The performance of the system was studied experimentally during the period 10.00AM: 2.00PM.
The experimental results show that the effective power produced for the PV panel increased by 15.5% (effective 10.0% ), 13.97% (effective 8.4% ) and 17.4% (effective 11.9% ) in case of front side, back side and both sides simultaneously cooling technique respectively in comparison with the non-cooled panel.
Furthermore, it was also possible to decrease panel temperature from an average 55 °C (non-cooled PV panel) to 27 °C, 32 °C and 24 °C in the case of front side, backside and simultaneous front and backside PV panel cooling respectively.
American Psychological Association (APA)
Khalil, A.& Abd al-Qayid, Muhammad& Hamdi, Muhammad. 2019. Performance improvement of pv panel using water cooling technology under Egyptian conditions. Journal of Engineering Research،Vol. 2019, no. 3، ج. 2, pp.42-47.
https://search.emarefa.net/detail/BIM-1363925
Modern Language Association (MLA)
Khalil, A.…[et al.]. Performance improvement of pv panel using water cooling technology under Egyptian conditions. Journal of Engineering Research No. 3, p. 2 (Jun. 2019), pp.42-47.
https://search.emarefa.net/detail/BIM-1363925
American Medical Association (AMA)
Khalil, A.& Abd al-Qayid, Muhammad& Hamdi, Muhammad. Performance improvement of pv panel using water cooling technology under Egyptian conditions. Journal of Engineering Research. 2019. Vol. 2019, no. 3، ج. 2, pp.42-47.
https://search.emarefa.net/detail/BIM-1363925
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 47
Record ID
BIM-1363925