Performance analysis of PV systems : case study of Palestine technical university (PTUK)‎ PV plant

Other Title(s)

تحليل أداء الأنظمة الشمسية الكهروضوئية : دراسة حالة لمحطة الطاقة الشمسية الكهروضوئية في جامعة فلسطين التقنية

Author

Ismail, Mahmud

Source

Palestine Technical University Kadoorie Research Journal

Issue

Vol. 9, Issue 1 (31 Mar. 2021), pp.10-21, 12 p.

Publisher

Palestine Technical University-Kadoorie

Publication Date

2021-03-31

Country of Publication

Palestine (West Bank)

No. of Pages

12

Main Subjects

Information Technology and Computer Science

Topics

Abstract AR

نسبة الأداء هي أحد المؤشرات المستخدمة لوصف فعالية الأنظمة الشمسية الكهروضوئية.

يمكن التحقق من استدامة النظام الشمسي الكهروضوئي عامًا بعد عام بالإضافة إلى موثوقيته عن طريق قياس نسبة الأداء كل عام.

سيمكننا هذا المؤشر أيضا من إجراء مقارنة بين أداء الأنظمة الشمسية الكهروضوئية المختلفة.

في هذا البحث، تم حساب نسب الأداء لخمسة أنظمة شمسية كهروضوئية مثبتة على أسطح بعض مباني جامعة فلسطين التقنية على أساس شهري و سنوي.

تم إجراء التحليل باستخدام البيانات المتوفرة (الطاقة المنتجة و الإشعاع الشمسي) لعام 2019.

لقد تبين أن نسبة الأداء لها قيم أعلى لشهري نيسان و ايلول مقارنة بالأشهر الأخرى.

من ناحية أخرى، تم الحصول على أدنى قيم لها في أشهر الشتاء.

يمكن ملاحظة هذا الاتجاه لجميع الانظمة المثبتة على مباني الجامعة الخمسة.

و عند الأخذ في الاعتبار كامل النظام المركب في الجامعة، كانت أعلى قيمة لنسبة الأداء 0.89 ، و التي كانت لشهر أيلول، في حين تم الحصول على أدنى قيمة عند 0.70 في كانون ثاني.

نسبة الأداء التي تم حسابها على أساس سنوي للنظام كاملا كانت 0.80.

عند النظر لكل نظام على حدة ، كانت أقل قيمة 0.44 لمبنى الخدمات الطلابية بينما كانت أعلى قيمة 0.94 لمبنى كلية العلوم.

Abstract EN

Performance ratio is one of the indicators used to describe the effectiveness of the PV systems.

The sustainability of the PV system year after year as well as its reliability can be checked by measuring the performance ratio each year.

This indicator will also enable us to carry out a comparison between the performances of different PV systems.

In this paper, the performance ratios for five PV systems installed on the roof tops of some of PTUK university buildings have been calculated on monthly and yearly basis.

The analysis has been carried out using the available data (energy production and solar irradiation) for the year 2019.

It was found that the performance ratio has higher values for May and September in comparison with other months.

On the other hand, its lowest values were obtained in winter months.

This trend can be observed for all of the PV clusters on the five buildings.

When taking into account the overall system, the highest value for the performance ratio was 0.89, which was for September, whereas its lowest value of 0.70 was obtained in January.

The performance ratio, which was calculated on yearly basis for the overall system, was found to be 0.80.

When considering each building separately, the lowest value was 0.44 for the “Services” building whereas the highest value was 0.94 for the Science building.

American Psychological Association (APA)

Ismail, Mahmud. 2021. Performance analysis of PV systems : case study of Palestine technical university (PTUK) PV plant. Palestine Technical University Kadoorie Research Journal،Vol. 9, no. 1, pp.10-21.
https://search.emarefa.net/detail/BIM-1380468

Modern Language Association (MLA)

Ismail, Mahmud. Performance analysis of PV systems : case study of Palestine technical university (PTUK) PV plant. Palestine Technical University Kadoorie Research Journal Vol. 9, no. 1 (2021), pp.10-21.
https://search.emarefa.net/detail/BIM-1380468

American Medical Association (AMA)

Ismail, Mahmud. Performance analysis of PV systems : case study of Palestine technical university (PTUK) PV plant. Palestine Technical University Kadoorie Research Journal. 2021. Vol. 9, no. 1, pp.10-21.
https://search.emarefa.net/detail/BIM-1380468

Data Type

Journal Articles

Language

English

Notes

Text in English ; abstracts in English and Arabic.

Record ID

BIM-1380468