Accurate determination of total antimony using ICP-MS and optimization its extraction efficiency from reference and soil samples

Joint Authors

Meisel, Thomas
Amirah, Samir
Wegsheider, Wolfhard

Source

Palestine Technical University Kadoorie Research Journal

Issue

Vol. 6, Issue 1 (30 Jun. 2018)3 p.

Publisher

Palestine Technical University-Kadoorie

Publication Date

2018-06-30

Country of Publication

Palestine (West Bank)

No. of Pages

3

Main Subjects

Social Sciences (Multidisciplinary)

Topics

Abstract EN

Two independent digestion techniques (microwave acid digestion with HF and HCl, HNO3 and Na2O2 sintering, respectively) were applied to determine the total Sb concentration in a real soil sample and in reference materials: Icelandic Basalt (BIR-1), Cody Shale (SCo-1) and (Soil-7).

ICP-MS was used to determine total antimony concentrations in the digested and the extracted solutions using external calibration and isotope dilution technique.

The recoveries of Sb using HF in the acids digestion mixture in closed-vessels microwave digestion system were excellent and the concentrations are in very good agreement with certified or reported concentrations of reference materials.

Using closed-vessels combined with microwave heating systems probably prevents the loss of volatile Sb compounds.

The use of hydrogen fluoride with other strong acid can help dissociating insoluble antimony silicates.

Different extraction reagents were tested for their ability to extract antimony using an ultrasonic bath namely: EDTA disodium salt, potassium hydroxide, citric acid monohydrate, pyridine-2,6-dicarboxylic acid, ammonium acetate, ammonium oxalate, ammonium thiocyanate, ammonium persulphate and di-ammonium hydrogen citrate.

A 500 mmol L-1 solution of citric acid pH 1.08 proved to be the most efficient extractant.

Optimization of the extraction conditions were investigated by studying the effect of pH, concentration, temperature, time of extraction, the ratio of sample mass to the volume of extractant and the number of consecutive extractions.

As a result three consecutive extractions for a total time of 45 min at 80 ˚C was the most efficient condition for Sb extraction.

Using these extraction conditions 61%, 3.7% RSD and 42%, 2.2% RSD (n=6) of the total antimony in the real soil and Soil-7 samples, respectively could be extracted.

American Psychological Association (APA)

Amirah, Samir& Meisel, Thomas& Wegsheider, Wolfhard. 2018. Accurate determination of total antimony using ICP-MS and optimization its extraction efficiency from reference and soil samples. Palestine Technical University Kadoorie Research Journal،Vol. 6, no. 1.
https://search.emarefa.net/detail/BIM-1381241

Modern Language Association (MLA)

Amirah, Samir…[et al.]. Accurate determination of total antimony using ICP-MS and optimization its extraction efficiency from reference and soil samples. Palestine Technical University Kadoorie Research Journal Vol. 6, no. 1 (2018).
https://search.emarefa.net/detail/BIM-1381241

American Medical Association (AMA)

Amirah, Samir& Meisel, Thomas& Wegsheider, Wolfhard. Accurate determination of total antimony using ICP-MS and optimization its extraction efficiency from reference and soil samples. Palestine Technical University Kadoorie Research Journal. 2018. Vol. 6, no. 1.
https://search.emarefa.net/detail/BIM-1381241

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1381241