Dynamic analysis of series-connected wound rotor induction motor
Author
Source
Issue
Vol. 1, Issue 4 (31 Dec. 2005), pp.1-16, 16 p.
Publisher
Publication Date
2005-12-31
Country of Publication
Algeria
No. of Pages
16
Main Subjects
Engineering & Technology Sciences (Multidisciplinary)
Topics
Abstract EN
Series-connected induction motor has the ability of operation either at two speeds ; the first one is less than the synchronous speed depending on the load, while the second speed is exactly double the synchronous speed.
The motor has the capability of self-starting to reach the first speed.
In addition to special arrangements required to attain the second (higher) speed, instability problems have been noted in experimental operation.
This paper presents a dynamic analysis of motor when supplied from a variable voltage variable frequency power supply.
The starting behavior has been presented.
Experimental results are given to check model validity in dynamic conditions.
Then the instability problem associated with high-speed operation has been studied to investigate its reasons and suggest solutions, either in operation or in the design.
American Psychological Association (APA)
Rashad, E. M.. 2005. Dynamic analysis of series-connected wound rotor induction motor. Journal of Electrical Systems،Vol. 1, no. 4, pp.1-16.
https://search.emarefa.net/detail/BIM-174021
Modern Language Association (MLA)
Rashad, E. M.. Dynamic analysis of series-connected wound rotor induction motor. Journal of Electrical Systems Vol. 1, no. 4 (Dec. 2005), pp.1-16.
https://search.emarefa.net/detail/BIM-174021
American Medical Association (AMA)
Rashad, E. M.. Dynamic analysis of series-connected wound rotor induction motor. Journal of Electrical Systems. 2005. Vol. 1, no. 4, pp.1-16.
https://search.emarefa.net/detail/BIM-174021
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 15
Record ID
BIM-174021