Investigating droplet separation efficiency in wire-mesh mist eliminators in bubble column

Joint Authors

al-Dughaither, Abd Allah A.
Ibrahim, Ahmad A.
al-Masri, Walid A.

Source

Journal of Saudi Chemical Society

Issue

Vol. 14, Issue 4 (31 Dec. 2010), pp.331-339, 9 p.

Publisher

Saudi Chemical Society

Publication Date

2010-12-31

Country of Publication

Saudi Arabia

No. of Pages

9

Main Subjects

Chemistry

Abstract EN

Effects of design parameters on performance of wire-mesh mist eliminators were experimentally investigated in 15 cm bubble column.

The demisters performances were evaluated by droplet collection efficiency as a function of wide ranges of operating and design parameters.

These parameters include : droplet size exiting the demister (250-380 nm), specific surface area (236-868m2 / m3), void fraction (97-98.3%), wire diameter (0.14-0.28 µm), packing density (130-240 kg /m3), and superficial gas velocity (0.109-0.118 m /s.

All demisters were 15 cm in diameter with 10 cm pad thickness, made from 316L stainless steel layered type demister pad wires.

Experiments were carried out using air-water system at ambient temperature and atmospheric pressure.

The experimental data on the droplet removal efficiency were obtained using Malvern Laser Droplet Sizer.

The removal efficiency was found to increase with the increasing the demister specific surface area, packing density, and superficial gas velocity.

In contrast, the removal efficiency was found to increase with decreasing the demister void fraction and wire diameter.

The separation efficiency is correlated empirically as a function of the design parameters.

A good agreement was obtained between the measured values and the correlation predictions with ± 5% accuracy.

American Psychological Association (APA)

al-Dughaither, Abd Allah A.& Ibrahim, Ahmad A.& al-Masri, Walid A.. 2010. Investigating droplet separation efficiency in wire-mesh mist eliminators in bubble column. Journal of Saudi Chemical Society،Vol. 14, no. 4, pp.331-339.
https://search.emarefa.net/detail/BIM-250278

Modern Language Association (MLA)

al-Masri, Walid A.…[et al.]. Investigating droplet separation efficiency in wire-mesh mist eliminators in bubble column. Journal of Saudi Chemical Society (Dec. 2010), pp.331-339.
https://search.emarefa.net/detail/BIM-250278

American Medical Association (AMA)

al-Dughaither, Abd Allah A.& Ibrahim, Ahmad A.& al-Masri, Walid A.. Investigating droplet separation efficiency in wire-mesh mist eliminators in bubble column. Journal of Saudi Chemical Society. 2010. Vol. 14, no. 4, pp.331-339.
https://search.emarefa.net/detail/BIM-250278

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 339

Record ID

BIM-250278