Use of Cr-39 polymer for radiation dosimetry
Other Title(s)
استخدام الكاشف النووي CR–39 في مجال القياسات الإشعاعية
Author
Source
Journal of King Abdulaziz University : Engineering Sciences
Issue
Vol. 22, Issue 1 (30 Jun. 2011), pp.79-96, 18 p.
Publisher
King Abdulaziz University Scientific Publishing Center
Publication Date
2011-06-30
Country of Publication
Saudi Arabia
No. of Pages
18
Main Subjects
Topics
Abstract AR
تناقش هذه الورقة العلمية نتائج دراسة الحث الحرضوئي لمادة البوليمر (CR-39) عند تعريضها لأشعة "جاما" و كذلك لجسيمات "بيتا".
إن توفر و رخص ثمن مادة البوليمر (CR-39)، يجعل من دراسة جدوى استخدامها لأغراض القياسات الإشعاعية الشخصية أمرا جديرا بالبحث.
و قد تم تقسيم الشرائج إلى مجموعتين : تم تعريض المجموعة الأولى من شرائح ال (CR-39) ذات أبعاد 3مم×3مم لأشعة "جاما" من مصدر "سيزيوم- 137" (Cs-137) : و تم تعريض المجموعة الثانية لجسيمات "بيتا" من مصدر "سترنشيوم-9-" (Sr-9-)، ثم تمت قراءة الانبعاثات الحر ضوئية الصادرة منها باستخدام قارئ (TLD) هارشو 4500 (Harshaw 4500).
تم تسخين شرائح ال (CR-39) عند درجات حرارة و فترات زمنية مختلفة لمعرفة درجة التسخين و الفترة الزمنية المثلى لمعالجة الشرائح و تنظيفها لأقصى حد.
تمت دراسة درجات حرارة التسخين على مدى واسع في قارئ (TL) لتحديد درجة الحرارة الأفضل الممكنة لتسخين شرائج (CR-39).
ان احتمالية تعزيز خاصية الانبعاث الحرضوئي لشرائح (CR-39) عند تعريضها لأشعة "جاما" في وجود عنصري الأكسجين و ثاني أكسيد الكربون قد تمت دراستها، و قد تبين لنا أن التحسن في خاصية الانبعاث الحرضوئي لشرائح (CR-39) عند تعريضها لجرعة من أشعة "جاما" في وجود الأكجسين أفضل منه في وجود ثاني أكسيد الكربون.
كما وجد أن التحسن في خاصية الانبعاث الحرضوئي لشرائح (CR-39) في وجود ثاني أكسيد الكربون أفضل منه في وجود الماء.
Abstract EN
This paper discusses the results of investigations of beta and gamma radiation induced thermoluminescence (TL) of CR-39 polymer.
As the material is cheap and easily available, the feasibility of CR-39 being used for personal dosimetry is worth investigating.
Samples from CR-39 of dimensions 3mm × 3mm were classified into two main groups.
The first group was irradiated with gamma rays from 137Cs source, while the second group was exposed to beta particles from 90Sr source and read for TL emission on a TLD reader, Harshaw 4500.
The chips were annealed at different temperatures to find out optimum annealing temperature to get rid of the background to a maximum.
Different annealing times were also studied for optimization.
The heating temperatures in the TL reader were studied in a wide range so as to assess the best possible heating temperature.
The possible enhancement of TL response of CR-39 exposed to gamma rays in the presence of oxygen and carbon dioxide was also studied.
Dose response of CR-39 exposed to gamma rays in the presence of oxygen is better than that in the presence of carbon dioxide.
The response of the exposed polymer in the presence of carbon dioxide is found to be better than that in the presence of air.
CR-39 polymer ; TL response ; 90Sr ; 137Cs ; Oxygen effect ; Carbon dioxide effect.
American Psychological Association (APA)
Tayyib, Zuhayr Abd Allah. 2011. Use of Cr-39 polymer for radiation dosimetry. Journal of King Abdulaziz University : Engineering Sciences،Vol. 22, no. 1, pp.79-96.
https://search.emarefa.net/detail/BIM-263692
Modern Language Association (MLA)
Tayyib, Zuhayr Abd Allah. Use of Cr-39 polymer for radiation dosimetry. Journal of King Abdulaziz University : Engineering Sciences Vol. 22, no. 1 (2011), pp.79-96.
https://search.emarefa.net/detail/BIM-263692
American Medical Association (AMA)
Tayyib, Zuhayr Abd Allah. Use of Cr-39 polymer for radiation dosimetry. Journal of King Abdulaziz University : Engineering Sciences. 2011. Vol. 22, no. 1, pp.79-96.
https://search.emarefa.net/detail/BIM-263692
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 93-94
Record ID
BIM-263692