Development and validation of an rp-hplc method for simultaneous analysis of ofloxacin and ornidazole in tablets
Other Title(s)
تطوير و تقييم فاعلية التحليل المتزامن للدوائين الافلوكساسين و الارنيدازول في الاقراص المنتجة باستخدام RP-HPLC جهاز
Joint Authors
Shakya, Ashok Kumar
Khalaf, Numan Abd al-Karim
Shurbaji, Mahir
Goindi, Diksha
Source
Jordan Journal of Pharmaceutical Sciences
Issue
Vol. 3, Issue 2 (31 Jul. 2010), pp.87-99, 13 p.
Publisher
University of Jordan Deanship of Academic Research (DAR)
Publication Date
2010-07-31
Country of Publication
Jordan
No. of Pages
13
Main Subjects
Pharmacy, Health & Medical Sciences
Abstract AR
تم تطوير طريقة خاصة بسيطة و حساسة بكلفة أقل باستخدام جهاز (HPLC) للقياس المتزامن لمادة الأفلوكساسين و الارنيدازول في التركيب الكيميائي الصيدلاني، و تمت عملية الفصل الكروماتوغرافي على عمود فصل راتنجي من نوع (BDS hypersil–C18) ذي الأبعاد التالية (250 ملم للطول و 4.6 مم للقطر الداخلي و 10 مايكرو ميتر لقطر الجسيمات) و تم استخدام الطور الناقل المتكون من 80% ماء (و المحتوى على 0.55 مليلتر لكل لتر من مادة ثلاثي ايثي أمين لتحسين شكل الإشارة التحليلية) و 20 % اسيتونايترايل و تم تعديل مقياس الأسس الهيدروجيني إلى 3.0باستخدام حامض الفسفوريك، و تم الكشف باستخدام طول موجة امتصاص 284 نانومتر و كانت الاستجابة بالدلالة الخطية للتركيز بمعدل 20-1 ميكروجرام لكل مليلتر للافلوكساسين و 2.5 .....50 ميكروجرام لكل مليليتر للارنيدازول، و كانت معاملات الارتباط 0.9998 و 0.9995 على التوالي، و مدى الكشف من 0.01 إلى 0.02 ميكروجرام لكل مليليتر من الأفلوكساسين و الارنيدازول على التوالي بينما وجد حد الكميات من 0.05 إلى 0.1ميكروجرام لكل مليلتر و كانت صحة النتيجة لكل من الأفلوكساسين و الارنيدازول عند (80 %)، و (100)، و (120 %) للدواء تتراوح بين (100.9-99.6) و كانت الدقة خلال اليوم و بين الأيام اقل من 1 % و كان وقت التمليص الكلي للدواءين أقل من تسع دقائق.
Abstract EN
A simple, sensitive, and inexpensive high performance liquid chromatographic method has been developed for simultaneous determination of ofloxacin and ornidazole in pharmaceutical formulations.
Chromatographic separation was achieved on a BDS-C18-Hypersil column (250 mm x 4.6 mm i.d., 10 μm).
Mobile phase was 80% water (containing 0.55 ml/L of triethylamine as peak modifier) and 20% acetonitrile; final pH was adjusted to 3.0 with orthophosphoric acid.
Detection was done at 284 nm.
Response was a linear function of concentration in the range 1–20 μg/ml for ofloxacin and 2.5-50 μg/ml for ornidazole; the correlation coefficients were 0.9998 and 0.9995, respectively.
The limit of detection were 0.01 and 0.02 μg/ml for ofloxacin and ornidazole respectively, where as limit of quantitation were 0.05 and 0.1 μg/ml .
The accuracy result for ofloxacin and ornidazole at eighty percent drug (80%), hundred percent (100%), and one hundred and twenty percent (120%) were ranged from 99.6-100.9%.
The inter- and intra-day precision was less than 1%.
Total elution time for the two components was less than 9 min.
Keywords: RP-HPLC, Ofloxacin, Ornidazole, Validation.
American Psychological Association (APA)
Khalaf, Numan Abd al-Karim& Shakya, Ashok Kumar& Shurbaji, Mahir& Goindi, Diksha. 2010. Development and validation of an rp-hplc method for simultaneous analysis of ofloxacin and ornidazole in tablets. Jordan Journal of Pharmaceutical Sciences،Vol. 3, no. 2, pp.87-99.
https://search.emarefa.net/detail/BIM-272691
Modern Language Association (MLA)
Shakya, Ashok Kumar…[et al.]. Development and validation of an rp-hplc method for simultaneous analysis of ofloxacin and ornidazole in tablets. Jordan Journal of Pharmaceutical Sciences Vol. 3, no. 2 (Jul. 2010), pp.87-99.
https://search.emarefa.net/detail/BIM-272691
American Medical Association (AMA)
Khalaf, Numan Abd al-Karim& Shakya, Ashok Kumar& Shurbaji, Mahir& Goindi, Diksha. Development and validation of an rp-hplc method for simultaneous analysis of ofloxacin and ornidazole in tablets. Jordan Journal of Pharmaceutical Sciences. 2010. Vol. 3, no. 2, pp.87-99.
https://search.emarefa.net/detail/BIM-272691
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 97-98
Record ID
BIM-272691