Effect of soldering on shear bond strength of porcelain fused to metal : In vitro study
Joint Authors
Ibrahim, Adil F.
al-Mahdi, Ahmad G.
Source
Journal of Baghdad College of Dentistry
Issue
Vol. 19, Issue 1 (31 Dec. 2007), pp.6-10, 5 p.
Publisher
University of Baghdad College of Dentistry
Publication Date
2007-12-31
Country of Publication
Iraq
No. of Pages
5
Main Subjects
Topics
Abstract EN
Background: The insertion of metal frameworks is critical during the fabrication of metal-ceramic restorations to ensure adequate fit to the abutments.
When fitness is inadequate, sectioning of the metal framework is required, which is then soldered in the dental laboratory.
Materials and Methods: Forty cylindrical metal (Ni-Cr alloy) specimens were prepared; it has 8 mm diameter and 3 mm height.
Half of these specimens were made in such a way so that it has perforation in the center of 1mm in diameter; the later group is then soldered.
All the samples were oxidized, and then sandblasted with aluminum oxide.
The ceramic material (vita VMK 95) was applied, the final thickness of ceramic was ١٫٥ mm, and then the samples was finished and glazed.
Half of the soldered and half of non soldered samples were stored in distilled water for one week, and then shear bond strength was evaluated for all samples.
After the testing, all samples were inspected visually and microscopically to detect the nature of failure.
Results and Conclusion: The result revealed that the intact specimens (non soldered) has higher shear bond strength values than the soldered specimens, and there is no influence of the water storage on shear bond strength for both groups.
The visual and microscopical observations show that the non soldered groups have higher percentage of cohesive failure than soldered groups which has higher percentage of adhesive failure.
Key words: Soldering, Porcelain fused to metal, shear bond test.
(J Bagh Coll Dentistry 2006; 19(1)6-10)
American Psychological Association (APA)
al-Mahdi, Ahmad G.& Ibrahim, Adil F.. 2007. Effect of soldering on shear bond strength of porcelain fused to metal : In vitro study. Journal of Baghdad College of Dentistry،Vol. 19, no. 1, pp.6-10.
https://search.emarefa.net/detail/BIM-288405
Modern Language Association (MLA)
al-Mahdi, Ahmad G.& Ibrahim, Adil F.. Effect of soldering on shear bond strength of porcelain fused to metal : In vitro study. Journal of Baghdad College of Dentistry Vol. 19, no. 1 (2007), pp.6-10.
https://search.emarefa.net/detail/BIM-288405
American Medical Association (AMA)
al-Mahdi, Ahmad G.& Ibrahim, Adil F.. Effect of soldering on shear bond strength of porcelain fused to metal : In vitro study. Journal of Baghdad College of Dentistry. 2007. Vol. 19, no. 1, pp.6-10.
https://search.emarefa.net/detail/BIM-288405
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 9-10
Record ID
BIM-288405