![](/images/graphics-bg.png)
Performance comparison of two-leg and three-leg ac voltage controller- fed three phase induction motor drive
Joint Authors
Source
Issue
Vol. 8, Issue 1 (31 Mar. 2012), pp.13-22, 10 p.
Publisher
Publication Date
2012-03-31
Country of Publication
Algeria
No. of Pages
10
Main Subjects
Abstract EN
This paper gives the comparison of the starting performance of three phase induction motor fed from three-leg and two-leg ac voltage controller.
Optimum firing angles are obtained for both the systems by considering various electrical characteristics like maximum positive and negative torque pulsations, peak starting current and acceleration time.
Two group of induction motors are utilized for comparative analysis of performance with the selected optimum firing angle.
Result shows that the performances of both the systems are on par.
Thus the cost effective, two-leg controller is the better choice for the induction motor starting.
American Psychological Association (APA)
Nafisah, K.& Jurj, Sali. 2012. Performance comparison of two-leg and three-leg ac voltage controller- fed three phase induction motor drive. Journal of Electrical Systems،Vol. 8, no. 1, pp.13-22.
https://search.emarefa.net/detail/BIM-290804
Modern Language Association (MLA)
Nafisah, K.& Jurj, Sali. Performance comparison of two-leg and three-leg ac voltage controller- fed three phase induction motor drive. Journal of Electrical Systems Vol. 8, no. 1 (Mar. 2012), pp.13-22.
https://search.emarefa.net/detail/BIM-290804
American Medical Association (AMA)
Nafisah, K.& Jurj, Sali. Performance comparison of two-leg and three-leg ac voltage controller- fed three phase induction motor drive. Journal of Electrical Systems. 2012. Vol. 8, no. 1, pp.13-22.
https://search.emarefa.net/detail/BIM-290804
Data Type
Journal Articles
Language
English
Notes
Includes appendix : p. 22
Record ID
BIM-290804