The use of the direct control of stator flux and kalman filter for the direct torque control of induction machine

Joint Authors

Menacer, A.
Benakcha, A.
Masudi, B.

Source

Journal of Electrical Systems

Issue

Vol. 2009, Issue 1 (30 Nov. 2009), pp.42-47, 6 p.

Publisher

Piercing Star House

Publication Date

2009-11-30

Country of Publication

Algeria

No. of Pages

6

Main Subjects

Electronic engineering

Topics

Abstract EN

The direct torque control is a good solution to problems related to robustness and dynamics encountered in vector control with rotor flux oriented.

The current research is directed towards improving the performance of this technique, whose the main problems are the evolution of the switching frequency, the ripples on the torque, on the flux and on the current.

In this paper, the main object is the development of a structure for the direct torque sensor using the extended Kalman filter in order to estimate the mechanical speed.

The simulation results show that this filter have a good performance (robustness) for different variations of the load and the noise measurement.

American Psychological Association (APA)

Menacer, A.& Benakcha, A.& Masudi, B.. 2009. The use of the direct control of stator flux and kalman filter for the direct torque control of induction machine. Journal of Electrical Systems،Vol. 2009, no. 1, pp.42-47.
https://search.emarefa.net/detail/BIM-291316

Modern Language Association (MLA)

Menacer, A.…[et al.]. The use of the direct control of stator flux and kalman filter for the direct torque control of induction machine. Journal of Electrical Systems No. 1 (Nov. 2009), pp.42-47.
https://search.emarefa.net/detail/BIM-291316

American Medical Association (AMA)

Menacer, A.& Benakcha, A.& Masudi, B.. The use of the direct control of stator flux and kalman filter for the direct torque control of induction machine. Journal of Electrical Systems. 2009. Vol. 2009, no. 1, pp.42-47.
https://search.emarefa.net/detail/BIM-291316

Data Type

Journal Articles

Language

English

Notes

Includes appendix : p. 46

Record ID

BIM-291316