Building signal conditioning for strain gauge sensors

Other Title(s)

إنشاء نظام تكييف إشارة مجسات قياس الإجهاد

Dissertant

Zurub, Ahmad A.

Thesis advisor

Abd al-Ati, Muhammad

University

Islamic University

Faculty

Faculty of Engineering

Department

Electrical Engineering Department

University Country

Palestine (Gaza Strip)

Degree

Master

Degree Date

2010

English Abstract

Strain gauge sensors are used extensively in industrial machines, testing equipments, and weighing indicators.

The output signal of these sensors is basically an analog voltage in the millivoltage range, and it needs to be monitored, measured, or analyzed. It is not suitable for direct input to popular analog to digital converters because of its low level, so it needs to be amplified using a suitable signal conditioner which is characterized by its precision, reliability, low power consumption, low price, and noise reduction.

Interfacing these sensors to a computer system is a challenging problem.

There are many popular solution strategies; therefore, designers must always deal with trade off among cost, accuracy, and reliability.

In this research, a real design problem is presented.

It is a rehabilitation of a Materials Testing Machine that was partially destroyed during the last war on Gaza.

Many possible solution strategies are described and the most suitable one to the case study is adopted.

We amplify the output signal from a strain gauge sensor using a precise signal conditioner designed circuit.

This amplified signal is filtered and input to a microcontroller and the value of the load is then monitored using liquid crystal display .The proposed design has been successfully implemented and the machine is returned back to work properly.

Main Subjects

Electronic engineering

Topics

No. of Pages

57

Table of Contents

Abstract.

Table of contents.

Chapter One : Introduction.

Chapter Two : Strain gauge sensors.

Chapter Three : Analog signal conditioning.

Chapter Four : Digital load cells.

Chapter Five : Rehabilitation of tensile testing machine.

Chapter Six : Conclusions and suggestions for future work.

References.

American Psychological Association (APA)

Zurub, Ahmad A.. (2010). Building signal conditioning for strain gauge sensors. (Master's theses Theses and Dissertations Master). Islamic University, Palestine (Gaza Strip)
https://search.emarefa.net/detail/BIM-301347

Modern Language Association (MLA)

Zurub, Ahmad A.. Building signal conditioning for strain gauge sensors. (Master's theses Theses and Dissertations Master). Islamic University. (2010).
https://search.emarefa.net/detail/BIM-301347

American Medical Association (AMA)

Zurub, Ahmad A.. (2010). Building signal conditioning for strain gauge sensors. (Master's theses Theses and Dissertations Master). Islamic University, Palestine (Gaza Strip)
https://search.emarefa.net/detail/BIM-301347

Language

English

Data Type

Arab Theses

Record ID

BIM-301347