Impact of TCSC on measured impedance by MHO distance relay on 400 kV Algerian transmission line in presence of phase to earth fault

Joint Authors

Chaghi, A.
Zellagui, M.

Source

Journal of Electrical Systems

Issue

Vol. 8, Issue 3 (30 Sep. 2012), pp.273-291, 19 p.

Publisher

Piercing Star House

Publication Date

2012-09-30

Country of Publication

Algeria

No. of Pages

19

Main Subjects

Electronic engineering

Topics

Abstract EN

This paper presents a study on the performances of distance relays setting in high voltage 400 kV in Eastern Algerian transmission networks at Sonelgaz Group (Algerian Company of Electricity and Gas) compensated by series Flexible AC.

Transmission System (FACTS) i.e Thyristor Controlled Series Capacitor (TCSC).

The facts are used for controlling transmission voltage, power flow, reactive power, and damping of power system oscillations in high power transfer levels.

The direct impacts of TCSC insertion on the total impedance of a protected transmission line (ZAB) and measured impedance (Zseen) by MHO distance relay are investigated in presence of phase to earth fault with fault resistance (RF) varied between 0 to 100 Ω.

The modified parameters of the protected transmission line have been calculated in order to improve the performances of distance relay protection to prevent circuit breaker nuisance tripping.

The simulation results performed in MATLAB software show the direct impact of TCSC when inserted in the midline transmission line on the measured impedance.

More, the effects of the RF and injected voltage VTCSC on the short-circuit calculation parameters and Zseen are presented.

American Psychological Association (APA)

Zellagui, M.& Chaghi, A.. 2012. Impact of TCSC on measured impedance by MHO distance relay on 400 kV Algerian transmission line in presence of phase to earth fault. Journal of Electrical Systems،Vol. 8, no. 3, pp.273-291.
https://search.emarefa.net/detail/BIM-313932

Modern Language Association (MLA)

Zellagui, M.& Chaghi, A.. Impact of TCSC on measured impedance by MHO distance relay on 400 kV Algerian transmission line in presence of phase to earth fault. Journal of Electrical Systems Vol. 8, no. 3 (Sep. 2012), pp.273-291.
https://search.emarefa.net/detail/BIM-313932

American Medical Association (AMA)

Zellagui, M.& Chaghi, A.. Impact of TCSC on measured impedance by MHO distance relay on 400 kV Algerian transmission line in presence of phase to earth fault. Journal of Electrical Systems. 2012. Vol. 8, no. 3, pp.273-291.
https://search.emarefa.net/detail/BIM-313932

Data Type

Journal Articles

Language

English

Notes

Includes appendices : p. 291

Record ID

BIM-313932