Prediction of equilibrium mixing index and optimum mixing time for three solid materials in fluidized column

Other Title(s)

التنبؤ بمعامل الخلط عند التوازن و زمن الخلط الأمثل لثلاثة مواد صلبة في عمود التميع

Joint Authors

Abbas, Ammar Salih
Salman, Rasha Habib
Slaymun, Abbas Hamid

Source

al-Khwarizmi Engineering Journal

Issue

Vol. 6, Issue 4 (31 Dec. 2010)10 p.

Publisher

University of Baghdad al-Khwarizmi College of Engineering

Publication Date

2010-12-31

Country of Publication

Iraq

No. of Pages

10

Main Subjects

Chemistry

Topics

Abstract AR

تم دراسة معامل الخلط عند الاتزان و معدل الخلط لمواد حرة الجريان باستخدام عمود هواء متميع.

المواد التي تم خلطها هي الرمل (قطر الجسيمات 0.7 ملم) و السكر (قطر الجسيمات 0.7 ملم) و برادة الحديد و هي تمثل المادة الكاشفة بتركيز 15 % وزنا.

معدل سرعة الهواء كان بين 0.45 و 0.65 م / ثا بينما زمن الخلط كان لحد 10 دقائق.

معامل الخلط لكل تجربة كان يحسب بأخذ عشرة نماذج ذات مواقع مختلفة قطريا و خطيا من عمود التميع ذو القطر الداخلي 150 ملم و ارتفاعه 900 ملم.

تم استخدام النتائج العملية في حل موديل رياضي لمعدل الخلط و معامل الخلط عند الاتزان مقترح من قبل Rose.

النتائج التجريبية استعملت لحل موديل رياضي لمعدل الجريان و معامل الخلط عند الاتزان اقترح من قبل Rose.

النتائج بينت أن معامل الخلط يزداد بزيادة سرعة الهواء و زمن الخلط حتى يصل للقيمة المثلى ثم ينخفض إلى أن يصل للاتزان.

نتائج معدل الخلط بينت اعتمادها على مقدار الفرق بين حجم جسيمات المادة الكاشفة.

أشار التحليل الإحصائي لكل من معامل الخلط النظري و العملي إلى أن الخطأ المعياري كان 0.92 % (حوالي 1 %) و معامل ارتباط 0.9857 و مجموع المتبقيات لتسع مشاهدات كان 0.002 لمستوى ثقة 95 %.

Abstract EN

Equilibrium and rate of mixing of free flowing solid materials are found using gas fluidized bed.

The solid materials were sand (size 0.7 mm), sugar (size0.7 mm) and 15 % cast iron used as a tracer.

The fluidizing gas was air with velocity ranged from 0.45-0.65 m / s while the mixing time was up to 10 minutes.

The mixing index for each experiment was calculated by averaging the results of 10 samples taken from different radial and axial positions in fluidized QVF column 150 mm ID and 900 mm height.

The experimental results were used in solving a mathematical model of mixing rate and mixing index at an equilibrium proposed by Rose.

The results show that mixing index increases with increasing air velocity and mixing time until it reaches an optimum value then decrease to an equilibrium value.

The results also show the dependency of the mixing index on the particle size of the tracer component.

The statistical analysis of the obtained theoretical mixing index versus the experimental mixing index shows that the standard error is 0.92 % (about 1 %) with the correlation coefficient of 0.9857 and the total residual of 0.002 for the ninth observation of the mixing index (theoretical versus experimental) over 95 % confidence level.

American Psychological Association (APA)

Slaymun, Abbas Hamid& Abbas, Ammar Salih& Salman, Rasha Habib. 2010. Prediction of equilibrium mixing index and optimum mixing time for three solid materials in fluidized column. al-Khwarizmi Engineering Journal،Vol. 6, no. 4.
https://search.emarefa.net/detail/BIM-325177

Modern Language Association (MLA)

Slaymun, Abbas Hamid…[et al.]. Prediction of equilibrium mixing index and optimum mixing time for three solid materials in fluidized column. al-Khwarizmi Engineering Journal Vol. 6, no. 4 (2010).
https://search.emarefa.net/detail/BIM-325177

American Medical Association (AMA)

Slaymun, Abbas Hamid& Abbas, Ammar Salih& Salman, Rasha Habib. Prediction of equilibrium mixing index and optimum mixing time for three solid materials in fluidized column. al-Khwarizmi Engineering Journal. 2010. Vol. 6, no. 4.
https://search.emarefa.net/detail/BIM-325177

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-325177