Simultaneous determination of cetirizine and pseudoephedrine combined in tablet dosage form by high performance liquid chromatography

Other Title(s)

التحديد المتزامن للستريزين و السودوفيدرين في الأقراص باستخدام الفصل الكروماتوغرافي عالي الكفاءة

Joint Authors

al-Mumani, Luayy
Abu Shandi, Khalid
Muhammad, Qasim D.
al-Sakit, Munib M.
al-Qaysi, Ali M.
Dibas, Fawaz
Masadah, Adnan M.
al-Ayid, Umar
Abu Namih, Iyad Samih M.

Source

Jordan Journal of Pharmaceutical Sciences

Issue

Vol. 6, Issue 2 (31 May. 2013), pp.188-202, 15 p.

Publisher

University of Jordan Deanship of Academic Research (DAR)

Publication Date

2013-05-31

Country of Publication

Jordan

No. of Pages

15

Main Subjects

Pharmacy, Health & Medical Sciences

Topics

Abstract AR

لقد تم تطوير طريقه سهلة و دقيقة وحساسة لتحليل الستريزين و السودوفيدرين بشكل متزامن باستخدام الفصل عالي الكفاءة موصولا بمحساس فوق بنفسجي على طول موجه220 نانومترا و ذلك في الأقراص الدوائية.

لقد تم استخدام عمود من نوع كربون 18 بطول 25 سم و نصف قطر داخلي 6.4 مليمتر.

إن الشكل المتحرك في النظام هو اسيتو نيترايل مع ماء بنسبة 540 إلى 470 إضافة إلى 200 مللي غرام من هبتان الصوديوم سلفونيك أسيد و من ثم تعديل الأس الهيدروجيني إلى 5.2 باستخدام حامض الكبريتيك.

لقد كانت نسبة الاسترجاع للستريزين و السودوفيدرين 2.98 إلى 9.102 % 5.99 A1 4.102 % U?1 C?C?1.

لقد كان منحنى المعايرة للستريزين من 2.12 إلى 5.36 مايكرو جرام لكل مليلتر بينما كان منحنى المعايرة للسودوفيدرين من 91.295 إلى 73.861 مايكرو جرام لكل مليلتر.

لقد كان الحد الأدنى للقياس 805.0 مايكرو جرام لكل مللتر للستريزين بينما كان الحد الأدنى للقياس للسودوفيدرين هو 978.17 مايكرو جرام لكل مليلتر و قد كان الحد الأدنى لتحديد و مشاهدة الستريزين و السودوفيدرين على الجهاز 685.2 و921.69 مايكرو جرام لكل مليلتر على التوالي.

Abstract EN

This study develops and validates an efficient, sensitive and simple method for the simultaneous determination of cetirizinedihydrochloride and pseudoephedrine combined in tablet dosage form by high performance liquid chromatography (HPLC) with an ultraviolet (UV) detector.

The validation of this method was carried out according to ICH and USP guidelines.

In this study, the mobile phase used was acetonitrile : water (530 : 470 (v / v) with 200mg sodium heptane sulfonic acid and the pH value was adjusted to 2.5 with sulfuric acid.

The limit of detection and quantification for cetirizinedihydrochloride were 0.805 and 2.685 μg / mL, respectively, and the limit of detection and quantification for pseudoephedrinewere17.976 and 59.921 μg / mL, respectively.

The linearity was studied in the concentration range of 12.2 and 36.5 μg / mL forcetirizinedihydrochloride and 295.91 and 861.73 μg / mL for pseudoephedrine.

The recovered amounts of cetirizinedihydrochloride and pseudoephedrine were 98.2 %-102.9 % and 99.5 %-102.4 %, respectively.

American Psychological Association (APA)

Abu Shandi, Khalid& Muhammad, Qasim D.& al-Sakit, Munib M.& al-Qaysi, Ali M.& Dibas, Fawaz& Masadah, Adnan M.…[et al.]. 2013. Simultaneous determination of cetirizine and pseudoephedrine combined in tablet dosage form by high performance liquid chromatography. Jordan Journal of Pharmaceutical Sciences،Vol. 6, no. 2, pp.188-202.
https://search.emarefa.net/detail/BIM-326185

Modern Language Association (MLA)

Abu Shandi, Khalid…[et al.]. Simultaneous determination of cetirizine and pseudoephedrine combined in tablet dosage form by high performance liquid chromatography. Jordan Journal of Pharmaceutical Sciences Vol. 6, no. 2 (2013), pp.188-202.
https://search.emarefa.net/detail/BIM-326185

American Medical Association (AMA)

Abu Shandi, Khalid& Muhammad, Qasim D.& al-Sakit, Munib M.& al-Qaysi, Ali M.& Dibas, Fawaz& Masadah, Adnan M.…[et al.]. Simultaneous determination of cetirizine and pseudoephedrine combined in tablet dosage form by high performance liquid chromatography. Jordan Journal of Pharmaceutical Sciences. 2013. Vol. 6, no. 2, pp.188-202.
https://search.emarefa.net/detail/BIM-326185

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 201

Record ID

BIM-326185