Sliding mode vector control of a PWM inverter fed induction motor

Joint Authors

al-Sabbagh, Qays S.
Salih, Ayman A.
Ahmad, Azzam M.

Source

Journal of Engineering

Issue

Vol. 14, Issue 4 (31 Dec. 2008), pp.3048-3067, 20 p.

Publisher

University of Baghdad College of Engineering

Publication Date

2008-12-31

Country of Publication

Iraq

No. of Pages

20

Main Subjects

Mechanical Engineering

Topics

Abstract AR

الهدف من هذا البحث هو تحليل و دراسة و محاكاة مسوق تيار متناوب لمحرك حثي ثلاثي الطور باستخدام استراتيجية السيطرة على اتجاه المجال (FOC) و باستخدام عاكس التيار العامل بتضمين عرض الموجة (PWM current regulated inverter) المستخدم لمسيطر التيار المتضمن حزمة الهسترة (Hysteresis band current controller).

تم تقديم النموذج الرياضي للمحرك الحثي و مبادئ سيطرة المجال (FO) غير المباشر.

تم استخدام المسيطر الإنزلاقي ذو المحددات (SMC-BL) كمسيطر للسرعة و مقارنته مع المسيطر التناسبي التكاملي (PI).

استخدام برنامج (Simulink / Matlab) لمحاكاة و تمثيل نموذج المحرك الحثي و المسيطرات (SMC-BL) و (PI) و المسيطر الاتجاهي الغير مباشر (IFOC).

و تمت المقارنة بين النتائج المستحصلة من تطبيق المسيطرا ت (SMC-BL) و (PI) من حيث الاستجابة الزمنية للسرعة و تأثير اضطرابات الحمل (load disturbance) على السرعة.

تم رسم و مناقشة النتائج المستحصلة من المحاكاة و المتضمنة خصائص المنظومة الجديدة و المنظومة القديمة.

أن النتائج النظرية أوضحت أن المنظومة الحديثة و التي تستخدم المسيطر الانزلاقي ذو المحددات هي جيدة جدا و هي أفضل من المنظومة القديمة من ناحية الاستجابة الزمنية للسرعة المختلفة و كذلك كبح تأثير الحمل على السرعة.

Abstract EN

The purpose of this paper is to analyze, study and simulate a three-phase induction motor drive using vector (field-oriented) control strategy and PWM current regulated inverter using hysteresis band current controller.

The mathematical model of the induction motor and the principle of indirect field-oriented control are introduced.

The Sliding Mode Controller with Boundary Layer (SMC-BL) is used as a speed controller and compared with the proportional integral (PI) controller.

A Simulink / Matlab program is written for simulating the induction motor model, SMC-BL and PI controllers and indirect field oriented control.

The SMC-BL based system and PI-controller based system are compared from the point of view of speed–time response and load disturbance.

The simulation results which illustrate the performance of SMC-BL based system and PI-controller based system are plotted and discussed.

These results obtained have shown improvement in the SMC-BL system performance from the point of view of variable speed tracking and load disturbance.

American Psychological Association (APA)

Salih, Ayman A.& al-Sabbagh, Qays S.& Ahmad, Azzam M.. 2008. Sliding mode vector control of a PWM inverter fed induction motor. Journal of Engineering،Vol. 14, no. 4, pp.3048-3067.
https://search.emarefa.net/detail/BIM-332407

Modern Language Association (MLA)

al-Sabbagh, Qays S.…[et al.]. Sliding mode vector control of a PWM inverter fed induction motor. Journal of Engineering Vol. 14, no. 4 (Dec. 2008), pp.3048-3067.
https://search.emarefa.net/detail/BIM-332407

American Medical Association (AMA)

Salih, Ayman A.& al-Sabbagh, Qays S.& Ahmad, Azzam M.. Sliding mode vector control of a PWM inverter fed induction motor. Journal of Engineering. 2008. Vol. 14, no. 4, pp.3048-3067.
https://search.emarefa.net/detail/BIM-332407

Data Type

Journal Articles

Language

English

Notes

Includes appendix : p. 3066-3067

Record ID