Detection of Exo A and OPR I genes in Pseudomonas aeruginosa using polymerase chain reaction

Other Title(s)

تحديد جينات exo A و oprI في Pseudomonas aeruginosa بإستعمال التفاعل السلسلي للبوليمريز

Author

Husayn, Sana Nuri

Source

Iraqi Journal of Biotechnology

Issue

Vol. 12, Issue 1 (30 Jun. 2013), pp.44-50, 7 p.

Publisher

University of Baghdad Genetic Engineering and Biotechnology for Postgraduate Studies

Publication Date

2013-06-30

Country of Publication

Iraq

No. of Pages

7

Main Subjects

Biology

Abstract AR

في هذه الدراسة، أنجز اختبارين للـ PCR كل على حدة للتشخيص الجزيئي للـ P.seudomonas aeruginosa المعزولة من عينات الجروح و الحروق.

استهدف جينين كمعلم خاص للـ P.aeruginosa، هما جين (exo A) exotoxin A و جين I lipoprotein للغشاء الخارجي (opr I).

خضعت سبعة عزلات لكل من P.aeruginosa و لكل من الأنواع الأخرى من جنس P.seudomonas في هذه الدراسة و استعمل العالق البكتيري المغلي كقالب دنا، أظهرت النتائج بأن جميع عزلات P.aeruginosa أعطت ناتج PCR موجب لجين oprI بحجم تضاعفي bp 196 بينما كانت 4 عزلات فقط موجبة لجين exo A بحجم تضاعفي bp 396.

أظهر ناتج PCR للـ Pseudomonas sp.

عدم إيجابية أي من العزلات السبعة لجين exo A و 4 فقط كانت موجبة لجين opr I.

يشير هذا البحث بأن التشخيص الجزيئي لـ P.aeruginosa المعزولة من عينات الجروح و الحروق باستعمال تقنية الـ PCR للتحري عن الجينين exo A و opr I هي طريقة سريعة.

Abstract EN

In this study, two polymerase chain reaction (PCR) assays were performed individually for the molecular detection of Pseudomonas aeruginosa obtained from wound and burn samples.

Two gene were targeted as specific markers for P.

aeruginosa namely the exotoxin A (exoA) gene and the outer membrane lipoprotein (oprI) gene.

Seven isolates for each of P.

aeruginosa and other Pseudomonas species were employed in this study and boiled bacterial suspension was used as a DNA template.

Results showed that all P.

aeruginosa isolates gave positive PCR product for oprI gene with amplified size (196 bp) while only 4isolates were harboring exo A gene with amplified size (396 bp).

Results for PCR product for Pseudomonas sp.

Revealed that none of the seven isolates were positive for exo A gene and only 4 were positive for opr I gene.

This research may indicates that molecular detection of P.

aeruginosa from wound and burn samples employing exo A and opr I genes by using PCR technique is a rapid method.

American Psychological Association (APA)

Husayn, Sana Nuri. 2013. Detection of Exo A and OPR I genes in Pseudomonas aeruginosa using polymerase chain reaction. Iraqi Journal of Biotechnology،Vol. 12, no. 1, pp.44-50.
https://search.emarefa.net/detail/BIM-342211

Modern Language Association (MLA)

Husayn, Sana Nuri. Detection of Exo A and OPR I genes in Pseudomonas aeruginosa using polymerase chain reaction. Iraqi Journal of Biotechnology Vol. 12, no. 1 (2013), pp.44-50.
https://search.emarefa.net/detail/BIM-342211

American Medical Association (AMA)

Husayn, Sana Nuri. Detection of Exo A and OPR I genes in Pseudomonas aeruginosa using polymerase chain reaction. Iraqi Journal of Biotechnology. 2013. Vol. 12, no. 1, pp.44-50.
https://search.emarefa.net/detail/BIM-342211

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 49-50

Record ID

BIM-342211