Spectrophotometric determination of Cr(VI)‎ Ions using new benzothiazolyl azo compound 2-[(6–methyl–2-benzothiazolyl)‎ azo] -4-chlorophenol

Joint Authors

al-Sharify, Abbas N. M.
Kazim, Qasim H.
Aqil Mahdi J.

Source

National Journal of Chemistry

Issue

Vol. 2006, Issue 24 (31 Dec. 2006), pp.608-619, 12 p.

Publisher

University of Babylon College of Sciences

Publication Date

2006-12-31

Country of Publication

Iraq

No. of Pages

12

Main Subjects

Chemistry

Abstract AR

حضر الكاشف العضوي الجديد 2-[(6-مثيل -2- بنزوثيازوليل)آوز]-4- كلورو فينول , و استخدام في التقدير الطيفي الآيون الكروم (VI), التفاعل بين الكاشف و أيون الكروم (VI) يتم عند دالة حامضية = 7.4 و امتصاصية المحلول تبقى ثابتة لأكثر من 24 ساعة.

الطريقة تسمح لتقدير أيونات الكروم ( ( VI ضمن مدى بين (0.2 – 9.0) ميكرو غرام.ملˉˡ , و بعامل امتصاص مولاري (0.772 ˣ 4 10 ) لتر .مول̄1 .

سم̄1 , وبحد كشف (0.16) مايكروغرام .ملֿ1.

تم حساب دقة الطريقة التحليلية و ضبطها فكانت قيم (=%R.S.D 0.449) و (Re %=98.67 ) و (1.33 =% (Erel.

درست طبيعة المعقد الذائب فكانت نسبة الفلز إلى الكاشف (2:1) عند دالة حامضية = 7.4 , و ثابت الأستقرارية (7.99×910) لتر² .مولֿ² , كما درست تداخلات الأيونات (pb²+ , Cu²+ , ֿ WO4²ֿ, MoO4²̄ , Hg²+ , Ni²+ , Cd²+ , Zn²+ ) و تأثير عوامل الحجب المختلفة على امتصاصية المعقد.

و أخيراً أجري تطبيق للطريقة المذكورة لتقدير آيون الكروم الكلي على هيئة الكروم (VI) في الماء المطروح من معمل دباغة النجف و كانت النتائج متوافقة مع نتائج تحليل (VI)Cr بواسطة مطيافية الامتصاص الذري اللهبي.

Abstract EN

The new reagent 2-[ ( 6 – Methyl – 2 – Benzothiazolyl ) azo ] – 4 - Chlorophenol (6-MeBTAClP) organic was synthesized, and used in the spectrophotometric determination of Cr (VI) ion .

Sensitive, selective and rapid method was proposed.

The reaction between the reagent and Cr(VI) ion occurs at pH = 7.4 , and the absorbance of the resultant solution remains stable for over 24 h.

The method allows for the determination of Cr(VI) over the range 0.2-9.0µg.ml-1, with molar absorptivity of 0.772x104 L.mol-1.cm-1 in chloroform solvent, and a detection limit of 0.16 µg.ml-1 .

Recovery and relative error values of precision and accuracy of method were found to be R.S.D%=0.449 , Re%=98.67 ,and Erel%=1.33.

Study of complex nature showed that metal: reagent ratio was 1:2 at pH=7.4 ,and the stability constant of (7.67 x 109) l2.

mol-2, the interferences of ions (Cu2+, Pb2+, Hg2+, Zn2+, Cd2+, Ni2+, MoO42-, WO4 2-) and masking agents effect on absorbance were also studied.

The above mentioned procedure was applied in the determination of total chromium in residual water of alnajaf dibajat factory as chromium(VI).

Results came in agreement with those obtained by flame atomic absorption method for determination of Cr (VI).

American Psychological Association (APA)

Aqil Mahdi J.& Kazim, Qasim H.& al-Sharify, Abbas N. M.. 2006. Spectrophotometric determination of Cr(VI) Ions using new benzothiazolyl azo compound 2-[(6–methyl–2-benzothiazolyl) azo] -4-chlorophenol. National Journal of Chemistry،Vol. 2006, no. 24, pp.608-619.
https://search.emarefa.net/detail/BIM-348951

Modern Language Association (MLA)

Aqil Mahdi J.…[et al.]. Spectrophotometric determination of Cr(VI) Ions using new benzothiazolyl azo compound 2-[(6–methyl–2-benzothiazolyl) azo] -4-chlorophenol. National Journal of Chemistry No. 24 (2006), pp.608-619.
https://search.emarefa.net/detail/BIM-348951

American Medical Association (AMA)

Aqil Mahdi J.& Kazim, Qasim H.& al-Sharify, Abbas N. M.. Spectrophotometric determination of Cr(VI) Ions using new benzothiazolyl azo compound 2-[(6–methyl–2-benzothiazolyl) azo] -4-chlorophenol. National Journal of Chemistry. 2006. Vol. 2006, no. 24, pp.608-619.
https://search.emarefa.net/detail/BIM-348951

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 518-519

Record ID

BIM-348951