Background : noise most frequently affects hearing system, as it may typically cause a bilateral, progressive sensorineural hearing loss at high frequencies.
Objectives : this study was designed to compare three different methods to evaluate noise-induced hearing loss (conventional audiometry, high-frequency audiometry, and distortion product otoacoustic emission).
Material and Methods : this was a cross-sectional study.
Data was analyzed by SPSS (ver.
19) using chi square, T test and repeated measures analysis.
Study samples were workers from tile and ceramic industry.
Results : we found that conventional audiometry, extended high-frequency audiometry, low-tone distortion product otoacoustic emission and high-tone distortion product otoacoustic emission had abnormal findings in 29 %, 69 %, 22 %, and 52 % of participants.
Most frequently affected frequencies were 4000 and 6000Hz in conventional audiometry, and 14000 and 16000 in extended high-frequency audiometry.
Conclusions : extended high-frequency audiometry was the most sensitive test for detection of hearing loss in workers exposed to hazardous noise compared with conventional audiometry and distortion product otoacoustic.
American Psychological Association (APA)
Mehrparvar, Amir Houshang& Mirmuhammadi, Sayyid Jalil& Davari, Muhammad Husayn& Mostaghaci, Mehrdad& Mollasadeghi, Abu al-Fadl& Bahaloo, Maryam…[et al.]. 2014. Conventional audiometry, extended high-frequency audiometry, and DPOAE for early diagnosis of NIHL. Iranian Red Crescent Medical Journal،Vol. 16, no. 1, pp.1-6.
https://search.emarefa.net/detail/BIM-350467
Modern Language Association (MLA)
Mehrparvar, Amir Houshang…[et al.]. Conventional audiometry, extended high-frequency audiometry, and DPOAE for early diagnosis of NIHL. Iranian Red Crescent Medical Journal Vol. 16, no. 1 (Jan. 2014), pp.1-6.
https://search.emarefa.net/detail/BIM-350467
American Medical Association (AMA)
Mehrparvar, Amir Houshang& Mirmuhammadi, Sayyid Jalil& Davari, Muhammad Husayn& Mostaghaci, Mehrdad& Mollasadeghi, Abu al-Fadl& Bahaloo, Maryam…[et al.]. Conventional audiometry, extended high-frequency audiometry, and DPOAE for early diagnosis of NIHL. Iranian Red Crescent Medical Journal. 2014. Vol. 16, no. 1, pp.1-6.
https://search.emarefa.net/detail/BIM-350467
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 5-6
Record ID
BIM-350467