Performance of pulsator clarifier (low turbidity)‎

Joint Authors

al-Duwayri, Salam K.
Shabib, Kazim Matar
Husayn, Rad M.

Source

Iraqi Journal of Chemical and Petroleum Engineering

Issue

Vol. 8, Issue 1 (31 Mar. 2007), pp.9-17, 9 p.

Publisher

University of Baghdad College of Engineering

Publication Date

2007-03-31

Country of Publication

Iraq

No. of Pages

9

Main Subjects

Chemistry

Topics

Abstract EN

Experimental and theoretical investigations are presented on flocculation process in pulsator clarifier.

Experimental system was designed to study the factors that affecting the performance of pulsator clarifier.

These factors were water level in vacuum chamber which range from 60 to 150 cm, rising time of water in vacuum chamber which having times of 20, 30 & 40 seconds, and sludge blanket height which having heights of 20, 30 & 40 cm.

The turbidity and pH of raw water used were 200 NTU and 8.13 respectively.

According to the jar test, the alum dose required for this turbidity was 20 mg/l.

The performance parameters of pulsator clarifier such as, turbidity, total solids TS, shear rate, volume concentration of sludge blanket and the flocculation criteria were studied.

It was observed that by decreasing the water level in vacuum tube and by increasing the rising time and sludge blanket height, low turbidity of output water attained.

Moreover, flocculation criteria value GCt was within the optimum range values (100-500).

A theoretical models was applied for total solids TS of output water.

The difference between experimental and theoretical data was ranged between (11-24)% of mean deviation at water level range of (125-150) cm and sludge blanket height 20 cm.

American Psychological Association (APA)

al-Duwayri, Salam K.& Husayn, Rad M.& Shabib, Kazim Matar. 2007. Performance of pulsator clarifier (low turbidity). Iraqi Journal of Chemical and Petroleum Engineering،Vol. 8, no. 1, pp.9-17.
https://search.emarefa.net/detail/BIM-353624

Modern Language Association (MLA)

al-Duwayri, Salam K.…[et al.]. Performance of pulsator clarifier (low turbidity). Iraqi Journal of Chemical and Petroleum Engineering Vol. 8, no. 1 (Mar. 2007), pp.9-17.
https://search.emarefa.net/detail/BIM-353624

American Medical Association (AMA)

al-Duwayri, Salam K.& Husayn, Rad M.& Shabib, Kazim Matar. Performance of pulsator clarifier (low turbidity). Iraqi Journal of Chemical and Petroleum Engineering. 2007. Vol. 8, no. 1, pp.9-17.
https://search.emarefa.net/detail/BIM-353624

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 16-17

Record ID

BIM-353624