Competitive stripping of multi-organic pollutants from contaminated water in bubble column semi-batch

Other Title(s)

الانتزاع التنافسي لخليط مركبات عضوية من الماء الملوث باستخدام برج الفقاعات في التجارب شبه الساكنة

Joint Authors

Salih, Walid Muhammad
Muhammad, Ahmad Abd
Hasan, Yasin Rashid

Source

Journal of Engineering

Issue

Vol. 20, Issue 3 (31 Mar. 2014), pp.28-40, 13 p.

Publisher

University of Baghdad College of Engineering

Publication Date

2014-03-31

Country of Publication

Iraq

No. of Pages

13

Main Subjects

Chemistry
Civil Engineering

Topics

Abstract AR

إن الانتزاع الهوائي لإزالة مركبات الترايكلورواثيلين (TCE)، الكلوروفورم (CF) و الدايكلوروميثلين (DCM) من الماء الملوث تمت دراسته باستخدام برج فقاعات (بقطر داخلي 0,073م و ارتفاع 1,08م مزود بعدة فتحات جانبية لغرض أخذ النماذج من مادة البلكسكلاس).

تم تحضير المحلول الملوث من المواد العضوية المتطايرة (VOCs) بمساعدة محلول الميثانول و تضاف إلى الماء المقطر، و بعد أن يحضر المحلول يوضع في خزان التغذية.

إن مركبات الـ (VOCs) المذكورة تحضر على شكل نظام فردي أو ثنائي أو ثلاثي.

و أما التراكيز المحضرة فتتراوح بين 50 ملغ / لتر إلى 250 ملغ / لتر.

لقد تم إجراء التجارب الشبه ساكنة و الذي يعتبر فيها برج الفقاعات كخزان خلط (Stirred Tank) و فقاعات الهواء تتحرك فيه من الأسفل إلى الأعلى في الماء الساكن.

تم احتساب تراكيز الـ (VOCs) من الطور السائل باستخدام النموذج الرياضي للفقاعات الهوائية (ABM).

و قد وجد إن القيم التجريبية مطابقة بشكل جيد مع النموذج المستخدم.

إن النتائج المستحصلة في التجارب أظهرت إن نسبة كفاءة إزالة المواد العضوية المتطايرة تزداد بزيادة معدل جريان الهواء أو زيادة معدل التغير الحجمي للهواء (Gas Holdup).

لقد وجد إن أفضل كفاءة إزالة عند 10=pH.

كما إن التجارب أظهرت إن مركب التراكلورواثيلين (TCE) يزال أسرع من المركبين الآخريين لكل الأنظمة، و خاصة في النظام المفرد.

إن قيم معامل انتقال المادة الحجمي (KLa) قد تم إيجادها لكل الحالات التي تم بحثها بضبط الـنموذج الرياضي BAM مع البيانات التجريبية.

و بشكل عام فقد وجد إن قيم KLa تزداد بزيادة معدل جريان الهواء و ان المركب TCE اظهر أعلى قيم لـ KLa.

Abstract EN

Air stripping for removal of Trichloroethylene (TCE), Chloroform (CF) and Dichloromethane (DCM) from water were studied in a bubble column (0.073 m inside dia.

and 1.08 m height with several sampling ports).

The contaminated water was prepared from deionized water and VOCs.

The presence of VOCs in feed solution was single, binary or ternary components.

They were diluted to the concentrations ranged between 50 mg/l to 250 mg/l.

The experiments were carried out in batch experiments which regard the bubble column as stirred tank and only gas was bubbled through stationary liquid.

In this case transient measurements of VOC concentration in the liquid phase and the measured concentration profiles were modeled by bubble aeration model (BAM) to fit the experimental data fairly well.

The results from batch experiments show that the removal efficiency of VOCs increases with increasing gas flow rate or gas holdup.

It is found a pH=10 give the best removal rate, but all experiments were adjusted at pH=8 which allow to study other operating conditions.

TCE is being removed faster than the other two components for all systems and a single component was removed faster than binary or ternary system.

The KLa values were evaluated by fitting the BAM to the experimental data.

It is found that KLa increased with increasing gas flow rate and TCE exhibits the highest KLa values.

American Psychological Association (APA)

Salih, Walid Muhammad& Muhammad, Ahmad Abd& Hasan, Yasin Rashid. 2014. Competitive stripping of multi-organic pollutants from contaminated water in bubble column semi-batch. Journal of Engineering،Vol. 20, no. 3, pp.28-40.
https://search.emarefa.net/detail/BIM-376868

Modern Language Association (MLA)

Salih, Walid Muhammad…[et al.]. Competitive stripping of multi-organic pollutants from contaminated water in bubble column semi-batch. Journal of Engineering Vol. 20, no. 3 (Mar. 2014), pp.28-40.
https://search.emarefa.net/detail/BIM-376868

American Medical Association (AMA)

Salih, Walid Muhammad& Muhammad, Ahmad Abd& Hasan, Yasin Rashid. Competitive stripping of multi-organic pollutants from contaminated water in bubble column semi-batch. Journal of Engineering. 2014. Vol. 20, no. 3, pp.28-40.
https://search.emarefa.net/detail/BIM-376868

Data Type

Journal Articles

Language

English

Notes

Includes appendices : p. 38-40

Record ID

BIM-376868