![](/images/graphics-bg.png)
Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry : Application to Bioequivalence Study
Joint Authors
Chandrasekhar, Kothapalli B.
Chandu, Babu Rao
Konda, Ravi Kumar
Challa, B. R.
Source
Journal of Analytical Methods in Chemistry
Issue
Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-8, 8 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2012-03-22
Country of Publication
Egypt
No. of Pages
8
Main Subjects
Abstract EN
A simple, sensitive, and rapid HPLC-MS/MS method was developed and validated for quantitative estimation of memantine in human plasma.
Chromatography was performed on Zorbax SB-C18 (4.6×75 mm, 3.5 μm) column.
Memantine (ME) and internal standard Memantine-d6(MED6) were extracted by using liquid-liquid extraction and analyzed by LC-ESI-MS/MS using multiple-reaction monitoring (MRM) mode.
The assay exhibited a linear dynamic range of 50.00–50000.00 pg/ml for ME in human plasma.
This method demonstrated an intra- and interday precision within the range of 2.1–3.7 and 1.4–7.8%, respectively.
Further intra- and interday accuracy was within the range of 95.6–99.8 and 95.7–99.1% correspondingly.
The mean recovery of ME and MED6 was 86.07±6.87 and 80.31±5.70%, respectively.
The described method was successfully employed in bioequivalence study of ME in Indian male healthy human volunteers under fasting conditions.
American Psychological Association (APA)
Konda, Ravi Kumar& Challa, B. R.& Chandu, Babu Rao& Chandrasekhar, Kothapalli B.. 2012. Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry : Application to Bioequivalence Study. Journal of Analytical Methods in Chemistry،Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-446361
Modern Language Association (MLA)
Konda, Ravi Kumar…[et al.]. Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry : Application to Bioequivalence Study. Journal of Analytical Methods in Chemistry No. 2012 (2012), pp.1-8.
https://search.emarefa.net/detail/BIM-446361
American Medical Association (AMA)
Konda, Ravi Kumar& Challa, B. R.& Chandu, Babu Rao& Chandrasekhar, Kothapalli B.. Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry : Application to Bioequivalence Study. Journal of Analytical Methods in Chemistry. 2012. Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-446361
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-446361