The Influence of Effective Energy on Computed Tomography Number Depends on Tissue Characteristics in Monoenergetic Cardiac Imaging

Joint Authors

Uemura, Shiro
Kawakami, Rika
Saito, Yoshihiko
Soeda, Tsunenari
Somekawa, Satoshi
Takami, Yasuhiro
Okayama, Satoshi

Source

Radiology Research and Practice

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-10-09

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Medicine

Abstract EN

Purpose.

To evaluate the influence of effective energy on computed tomography (CT) number in monoenergetic images (MEIs).

Methods.

Three bottle phantoms filled with water, oil, and a contrast agent were scanned at 100 and 140 kVp tube energy with a dual-source CT scanner.

Cardiac dual-energy CT data was collected from 17 patients.

CT numbers were measured in the 3 phantom materials and in the left ventricular cavity, myocardium, pericardial fat, and vertebral bone in MEIs from 40 to 190 keV.

Results.

In the phantoms, the mean CT number increased in oil whereas it decreased in the contrast agent as the energy level increased (P<0.001).

In clinical subjects, the mean CT numbers for the left ventricular cavity, myocardium, and vertebral bone were highest in the 40 keV images (P<0.001) and decreased as the energy level increased.

In contrast, the CT number for pericardial fat was lowest in the 40 keV images (P<0.001) and increased with increasing energy.

Conclusions.

The influence of effective energy on CT number varies with material and tissue type in monoenergetic cardiac imaging, which could evaluate tissue characteristics through assessment of the changes in CT number associated with effective energies.

American Psychological Association (APA)

Okayama, Satoshi& Soeda, Tsunenari& Takami, Yasuhiro& Kawakami, Rika& Somekawa, Satoshi& Uemura, Shiro…[et al.]. 2012. The Influence of Effective Energy on Computed Tomography Number Depends on Tissue Characteristics in Monoenergetic Cardiac Imaging. Radiology Research and Practice،Vol. 2012, no. 2012, pp.1-7.
https://search.emarefa.net/detail/BIM-449846

Modern Language Association (MLA)

Okayama, Satoshi…[et al.]. The Influence of Effective Energy on Computed Tomography Number Depends on Tissue Characteristics in Monoenergetic Cardiac Imaging. Radiology Research and Practice No. 2012 (2012), pp.1-7.
https://search.emarefa.net/detail/BIM-449846

American Medical Association (AMA)

Okayama, Satoshi& Soeda, Tsunenari& Takami, Yasuhiro& Kawakami, Rika& Somekawa, Satoshi& Uemura, Shiro…[et al.]. The Influence of Effective Energy on Computed Tomography Number Depends on Tissue Characteristics in Monoenergetic Cardiac Imaging. Radiology Research and Practice. 2012. Vol. 2012, no. 2012, pp.1-7.
https://search.emarefa.net/detail/BIM-449846

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-449846