Protocol for Evaluation of Robotic Technology in Orthopedic Surgery

Joint Authors

Cobb, Justin P.
Jaffry, Zahra
Masjedi, Milad
Harris, Simon

Source

Advances in Orthopedics

Issue

Vol. 2013, Issue 2013 (31 Dec. 2013), pp.1-5, 5 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2013-09-19

Country of Publication

Egypt

No. of Pages

5

Main Subjects

Medicine

Abstract EN

In recent years, robots have become commonplace in surgical procedures due to their high accuracy and repeatability.

The Acrobot Sculptor is an example of such a robot that can assist with unicompartmental knee replacement.

In this study, we aim to evaluate the accuracy of the robot (software and hardware) in a clinical setting.

We looked at (1) segmentation by comparing the segmented data from Sculptor software to other commercial software, (2) registration by checking the inter- and intraobserver repeatability of selecting set points, and finally (3) sculpting (n=9 cases) by evaluating the achieved implant position and orientation relative to that planned.

The results from segmentation and registration were found to be accurate.

The highest error was observed in flexion extension orientation of femoral implant (0.4±3.7°).

Mean compound rotational and translational errors for both components were 2.1±0.6 mm and 3±0.8° for tibia and 2.4±1.2 mm and 4.3±1.4° for the femur.

The results from all processes used in Acrobot were small.

Validation of robot in clinical settings is highly vital to ensure a good outcome for patients.

It is therefore recommended to follow the protocol used here on other available similar products.

American Psychological Association (APA)

Masjedi, Milad& Jaffry, Zahra& Harris, Simon& Cobb, Justin P.. 2013. Protocol for Evaluation of Robotic Technology in Orthopedic Surgery. Advances in Orthopedics،Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-453536

Modern Language Association (MLA)

Masjedi, Milad…[et al.]. Protocol for Evaluation of Robotic Technology in Orthopedic Surgery. Advances in Orthopedics No. 2013 (2013), pp.1-5.
https://search.emarefa.net/detail/BIM-453536

American Medical Association (AMA)

Masjedi, Milad& Jaffry, Zahra& Harris, Simon& Cobb, Justin P.. Protocol for Evaluation of Robotic Technology in Orthopedic Surgery. Advances in Orthopedics. 2013. Vol. 2013, no. 2013, pp.1-5.
https://search.emarefa.net/detail/BIM-453536

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-453536