Comparison of LC-MS Assay and HPLC Assay of Busulfan in Clinical Pharmacokinetics Studies

Joint Authors

Gounder, Murugesan K.
Goodin, Susan
DiPaola, Robert S.
Lin, Hongxia
Strair, Roger K.

Source

ISRN Analytical Chemistry

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-5, 5 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-02-19

Country of Publication

Egypt

No. of Pages

5

Main Subjects

Chemistry

Abstract EN

Busulfan is used in preparative regimens for bone marrow transplantation and timely busulfan plasma concentration reporting is critical for subsequent dose adjustment.

We compared two sensitive methods for pharmacokinetics studies including LC-MS assay and HPLC precolumn derivatization assay.

Chromatographic separation was performed on a Gemini C18 column.

Liquid-liquid extraction with ethyl acetate was used for plasma sample preparation.

Busulfan and internal standard ([2H8]-busulfan) were detected as ammonium adducts at m/z 264.2 and 272.2 for LC-MS assay.

For HPLC assay, the extraction from plasma was derivatized with 2-naphathalenethiol using synthesized internal standard (1,6-(methanesulfonyloxy)octane).

The Ex and Em wavelength was 255 nm and 370 nm.

The limit of detection was 15.6 ng/mL and 7.8 ng/mL for HPLC and LC-MS assay and good linearity ranging from 31.25–1000 ng/mL for HPLC and 15.6-1000 ng/mL for LC-MS assay.

The intra and interday assay precision were less than 9.2% and 12.0% for LC-MS and HPLC assay.

The pharmacokinetic parameters were estimated using noncompartmental pharmacokinetic model with WinNonlin.

Busulfan AUClast showed an average difference of 0.7% between the two methods.

The LC-MS method is accurate, reproducible, and requires less specimen, sample preparation and analysis time over the HPLC assay, making busulfan monitoring faster and easier in clinical practice.

American Psychological Association (APA)

Lin, Hongxia& Goodin, Susan& Strair, Roger K.& DiPaola, Robert S.& Gounder, Murugesan K.. 2012. Comparison of LC-MS Assay and HPLC Assay of Busulfan in Clinical Pharmacokinetics Studies. ISRN Analytical Chemistry،Vol. 2012, no. 2012, pp.1-5.
https://search.emarefa.net/detail/BIM-453917

Modern Language Association (MLA)

Lin, Hongxia…[et al.]. Comparison of LC-MS Assay and HPLC Assay of Busulfan in Clinical Pharmacokinetics Studies. ISRN Analytical Chemistry No. 2012 (2012), pp.1-5.
https://search.emarefa.net/detail/BIM-453917

American Medical Association (AMA)

Lin, Hongxia& Goodin, Susan& Strair, Roger K.& DiPaola, Robert S.& Gounder, Murugesan K.. Comparison of LC-MS Assay and HPLC Assay of Busulfan in Clinical Pharmacokinetics Studies. ISRN Analytical Chemistry. 2012. Vol. 2012, no. 2012, pp.1-5.
https://search.emarefa.net/detail/BIM-453917

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references