A More Reliable Method for Monitoring the Condition of Three-Phase Induction Motors Based on Their Vibrations

Joint Authors

Ibrahim, Ghalib R.
Abouhnik, A.
Shnibha, Rmdan
Albarbar, A.

Source

ISRN Mechanical Engineering

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-9, 9 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-10-18

Country of Publication

Egypt

No. of Pages

9

Main Subjects

Mechanical Engineering

Abstract EN

This paper is concerned with accurate, early, and reliable fault diagnosis using an enhanced vibration measurement technique based on short-time Fourier transform.

The novelty of this work lies in detecting very low-phase imbalance-related faults.

The energy contained within specified frequency bands centred on the rotor frequency and power supply frequency, and their sideband zones were calculated.

The technique was firstly demonstrated by simulated signals and then verified by experimental measurements taken from two different-sized test rigs.

The first one comprised a 1.1 kW variable speed three-phase induction motor with varying output load (no load, 25%, 50%, 75%, and 100% load).

Two types of common faults were introduced: imbalance in one phase as the electrical fault and misalignment of load as the mechanical fault.

The second test rig had a 3 kW three-phase induction motor again with varying load, and here the two seeded faults were: phase imbalance and one broken rotor bar.

The measured energy levels in the test conditions were found to be affected by type of fault and fault severity.

It is concluded that the proposed method offers a potentially reliable and computationally inexpensive condition monitoring tool which can be implemented with real-time monitoring systems.

American Psychological Association (APA)

Shnibha, Rmdan& Albarbar, A.& Abouhnik, A.& Ibrahim, Ghalib R.. 2012. A More Reliable Method for Monitoring the Condition of Three-Phase Induction Motors Based on Their Vibrations. ISRN Mechanical Engineering،Vol. 2012, no. 2012, pp.1-9.
https://search.emarefa.net/detail/BIM-455672

Modern Language Association (MLA)

Shnibha, Rmdan…[et al.]. A More Reliable Method for Monitoring the Condition of Three-Phase Induction Motors Based on Their Vibrations. ISRN Mechanical Engineering No. 2012 (2012), pp.1-9.
https://search.emarefa.net/detail/BIM-455672

American Medical Association (AMA)

Shnibha, Rmdan& Albarbar, A.& Abouhnik, A.& Ibrahim, Ghalib R.. A More Reliable Method for Monitoring the Condition of Three-Phase Induction Motors Based on Their Vibrations. ISRN Mechanical Engineering. 2012. Vol. 2012, no. 2012, pp.1-9.
https://search.emarefa.net/detail/BIM-455672

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-455672