A More Reliable Method for Monitoring the Condition of Three-Phase Induction Motors Based on Their Vibrations
Joint Authors
Ibrahim, Ghalib R.
Abouhnik, A.
Shnibha, Rmdan
Albarbar, A.
Source
Issue
Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-9, 9 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2012-10-18
Country of Publication
Egypt
No. of Pages
9
Main Subjects
Abstract EN
This paper is concerned with accurate, early, and reliable fault diagnosis using an enhanced vibration measurement technique based on short-time Fourier transform.
The novelty of this work lies in detecting very low-phase imbalance-related faults.
The energy contained within specified frequency bands centred on the rotor frequency and power supply frequency, and their sideband zones were calculated.
The technique was firstly demonstrated by simulated signals and then verified by experimental measurements taken from two different-sized test rigs.
The first one comprised a 1.1 kW variable speed three-phase induction motor with varying output load (no load, 25%, 50%, 75%, and 100% load).
Two types of common faults were introduced: imbalance in one phase as the electrical fault and misalignment of load as the mechanical fault.
The second test rig had a 3 kW three-phase induction motor again with varying load, and here the two seeded faults were: phase imbalance and one broken rotor bar.
The measured energy levels in the test conditions were found to be affected by type of fault and fault severity.
It is concluded that the proposed method offers a potentially reliable and computationally inexpensive condition monitoring tool which can be implemented with real-time monitoring systems.
American Psychological Association (APA)
Shnibha, Rmdan& Albarbar, A.& Abouhnik, A.& Ibrahim, Ghalib R.. 2012. A More Reliable Method for Monitoring the Condition of Three-Phase Induction Motors Based on Their Vibrations. ISRN Mechanical Engineering،Vol. 2012, no. 2012, pp.1-9.
https://search.emarefa.net/detail/BIM-455672
Modern Language Association (MLA)
Shnibha, Rmdan…[et al.]. A More Reliable Method for Monitoring the Condition of Three-Phase Induction Motors Based on Their Vibrations. ISRN Mechanical Engineering No. 2012 (2012), pp.1-9.
https://search.emarefa.net/detail/BIM-455672
American Medical Association (AMA)
Shnibha, Rmdan& Albarbar, A.& Abouhnik, A.& Ibrahim, Ghalib R.. A More Reliable Method for Monitoring the Condition of Three-Phase Induction Motors Based on Their Vibrations. ISRN Mechanical Engineering. 2012. Vol. 2012, no. 2012, pp.1-9.
https://search.emarefa.net/detail/BIM-455672
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID