Abstract EN

Press-fit, hydroxyapatite-coated acetabular cup designs may offer a lower incidence of loosening and migration than older designs.

Our study evaluated the initial clinical and radiographic success of a cementless acetabular shell in a large cohort of primary total hip arthroplasty (THA) patients.

We queried our institution’s prospectively collected registry for a series of 771 primary THAs (695 patients) implanted with this cup by 4 high-volume arthroplasty surgeons.

Of the 613 hips with minimum 2-year followup, average HHS (Harris Hip Score) was 93.6, WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) was 87.6, and VAS (Visual Analog Scale) pain score was 1.2.

While there was a 2% reoperation rate (12 hips), none of the cups were revised for aseptic loosening.

No radiolucencies were found and there was no evidence of acetabular loosening.

At early followup, this newer cementless acetabular cup implant design exhibits high survivorship and clinical success.

American Psychological Association (APA)

Wang, John& DiPietro, James& Bostrom, Mathias& Nestor, Bryan& Padgett, Douglas& Westrich, Geoffrey. 2014. Clinical and Radiographic Outcomes with a Hydroxyapatite and Porous Coated Cup Design. Advances in Orthopedic Surgery،Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-461753

Modern Language Association (MLA)

Wang, John…[et al.]. Clinical and Radiographic Outcomes with a Hydroxyapatite and Porous Coated Cup Design. Advances in Orthopedic Surgery No. 2014 (2014), pp.1-5.
https://search.emarefa.net/detail/BIM-461753

American Medical Association (AMA)

Wang, John& DiPietro, James& Bostrom, Mathias& Nestor, Bryan& Padgett, Douglas& Westrich, Geoffrey. Clinical and Radiographic Outcomes with a Hydroxyapatite and Porous Coated Cup Design. Advances in Orthopedic Surgery. 2014. Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-461753

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-461753