Abstract EN

A process heat exchanger (PHE) is a key component for transferring the high-temperature heat generated from a very high-temperature reactor (VHTR) to a chemical reaction for the massive production of hydrogen.

The Korea Atomic Energy Research Institute has designed and assembled a small-scale nitrogen gas loop for a performance test on VHTR components and has manufactured a small-scale PHE prototype made of Hastelloy-X alloy.

A performance test on the PHE prototype is underway in the gas loop, where different kinds of pipelines connecting to the PHE prototype are tested for reducing the thermal stress under the expansion of the PHE prototype.

In this study, to evaluate the high-temperature structural integrity of the PHE prototype under the test condition of the gas loop, a realistic and effective boundary condition imposing the stiffness of the pipelines connected to the PHE prototype was suggested.

An equivalent spring stiffness to reduce the thermal stress under the expansion of the PHE prototype was computed from the bending deformation and expansion of the pipelines connected to the PHE.

A structural analysis on the PHE prototype was also carried out by imposing the suggested boundary condition.

As a result of the analysis, the structural integrity of the PHE prototype seems to be maintained under the test condition of the gas loop.

American Psychological Association (APA)

Song, Kee-nam& Hong, Sung-deok& Park, Hong-Yoon. 2012. High-Temperature Structural Analysis of a Small-Scale PHE Prototype under the Test Condition of a Small-Scale Gas Loop. Science and Technology of Nuclear Installations،Vol. 2012, no. 2012, pp.1-10.
https://search.emarefa.net/detail/BIM-462525

Modern Language Association (MLA)

Song, Kee-nam…[et al.]. High-Temperature Structural Analysis of a Small-Scale PHE Prototype under the Test Condition of a Small-Scale Gas Loop. Science and Technology of Nuclear Installations No. 2012 (2012), pp.1-10.
https://search.emarefa.net/detail/BIM-462525

American Medical Association (AMA)

Song, Kee-nam& Hong, Sung-deok& Park, Hong-Yoon. High-Temperature Structural Analysis of a Small-Scale PHE Prototype under the Test Condition of a Small-Scale Gas Loop. Science and Technology of Nuclear Installations. 2012. Vol. 2012, no. 2012, pp.1-10.
https://search.emarefa.net/detail/BIM-462525

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-462525