Ultrasound Common Carotid Artery Segmentation Based on Active Shape Model

Joint Authors

Wu, Huihui
Yuchi, Ming
Xu, Mengling
Yang, Xin
Jin, Jiaoying
He, Wanji
Ding, Mingyue

Source

Computational and Mathematical Methods in Medicine

Issue

Vol. 2013, Issue 2013 (31 Dec. 2013), pp.1-11, 11 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2013-03-06

Country of Publication

Egypt

No. of Pages

11

Main Subjects

Medicine

Abstract EN

Carotid atherosclerosis is a major reason of stroke, a leading cause of death and disability.

In this paper, a segmentation method based on Active Shape Model (ASM) is developed and evaluated to outline common carotid artery (CCA) for carotid atherosclerosis computer-aided evaluation and diagnosis.

The proposed method is used to segment both media-adventitia-boundary (MAB) and lumen-intima-boundary (LIB) on transverse views slices from three-dimensional ultrasound (3D US) images.

The data set consists of sixty-eight, 17 × 2 × 2, 3D US volume data acquired from the left and right carotid arteries of seventeen patients (eight treated with 80 mg atorvastatin and nine with placebo), who had carotid stenosis of 60% or more, at baseline and after three months of treatment.

Manually outlined boundaries by expert are adopted as the ground truth for evaluation.

For the MAB and LIB segmentations, respectively, the algorithm yielded Dice Similarity Coefficient (DSC) of 94.4% ± 3.2% and 92.8% ± 3.3%, mean absolute distances (MAD) of 0.26 ± 0.18 mm and 0.33 ± 0.21 mm, and maximum absolute distances (MAXD) of 0.75 ± 0.46 mm and 0.84 ± 0.39 mm.

It took 4.3 ± 0.5 mins to segment single 3D US images, while it took 11.7 ± 1.2 mins for manual segmentation.

The method would promote the translation of carotid 3D US to clinical care for the monitoring of the atherosclerotic disease progression and regression.

American Psychological Association (APA)

Yang, Xin& Jin, Jiaoying& Xu, Mengling& Wu, Huihui& He, Wanji& Yuchi, Ming…[et al.]. 2013. Ultrasound Common Carotid Artery Segmentation Based on Active Shape Model. Computational and Mathematical Methods in Medicine،Vol. 2013, no. 2013, pp.1-11.
https://search.emarefa.net/detail/BIM-464515

Modern Language Association (MLA)

Yang, Xin…[et al.]. Ultrasound Common Carotid Artery Segmentation Based on Active Shape Model. Computational and Mathematical Methods in Medicine No. 2013 (2013), pp.1-11.
https://search.emarefa.net/detail/BIM-464515

American Medical Association (AMA)

Yang, Xin& Jin, Jiaoying& Xu, Mengling& Wu, Huihui& He, Wanji& Yuchi, Ming…[et al.]. Ultrasound Common Carotid Artery Segmentation Based on Active Shape Model. Computational and Mathematical Methods in Medicine. 2013. Vol. 2013, no. 2013, pp.1-11.
https://search.emarefa.net/detail/BIM-464515

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-464515