Surgical Ligation of Extrahepatic Shunt under Guidance of Doppler Ultrasound, Portography, and Portal Pressure Monitoring

Joint Authors

Shimizu, Takayuki
Kubota, Keiichi
Shimoda, Mitsugi

Source

Case Reports in Surgery

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-08-13

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Medicine

Abstract EN

A 54-year-old man with chronic hepatitis C was admitted to our hospital because of a disturbance of consciousness and hyperammonemia.

Abdominal angiography revealed a portosystemic shunt between the superior mesenteric vein and inferior vena cava.

Endoscopic examination showed no varix.

As interventional treatment was unsuccessful, surgical ligation of the shunt was performed.

After surgery, portography revealed a huge shunt.

Before ligation, the portal pressure, portal flow speed, and volume at the umbilical portion were 24 H2O.

5.6 cm/s and 203 ml/min, respectively.

Finally the shunt was ligated.

The portal flow speed and volume increased for 14 days following surgery and then stabilized.

No varices were observed postoperatively.

Doppler ultrasound, portography, and portal pressure monitoring can be used to reveal haemodynamic changes in the portal system and justify surgical ligation of portosystemic shunt.

American Psychological Association (APA)

Shimoda, Mitsugi& Shimizu, Takayuki& Kubota, Keiichi. 2012. Surgical Ligation of Extrahepatic Shunt under Guidance of Doppler Ultrasound, Portography, and Portal Pressure Monitoring. Case Reports in Surgery،Vol. 2012, no. 2012, pp.1-3.
https://search.emarefa.net/detail/BIM-464585

Modern Language Association (MLA)

Shimoda, Mitsugi…[et al.]. Surgical Ligation of Extrahepatic Shunt under Guidance of Doppler Ultrasound, Portography, and Portal Pressure Monitoring. Case Reports in Surgery No. 2012 (2012), pp.1-3.
https://search.emarefa.net/detail/BIM-464585

American Medical Association (AMA)

Shimoda, Mitsugi& Shimizu, Takayuki& Kubota, Keiichi. Surgical Ligation of Extrahepatic Shunt under Guidance of Doppler Ultrasound, Portography, and Portal Pressure Monitoring. Case Reports in Surgery. 2012. Vol. 2012, no. 2012, pp.1-3.
https://search.emarefa.net/detail/BIM-464585

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-464585