Simplified Technique for Sealing Corneal Perforations Using a Fibrin Glue-Assisted Amniotic Membrane Transplant-Plug

Joint Authors

Ersan, Ismail
Kara, Selcuk
Arikan, Sedat
Taskiran Comez, Arzu

Source

Case Reports in Ophthalmological Medicine

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-06-18

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Diseases

Abstract EN

Purpose.

To describe a surgical technique using amniotic membrane transplant (AMT) with fibrin glue (FG) for treating smaller corneal perforations more practically and appropriately filling the defect.

Method.

A patient with noninfectious central corneal perforation, in 1 mm in diameter, was treated with FG-assisted AMT-plug.

An AMT was folded in on itself twice by using FG then a small piece of this FG-AMT mixture was cut to maintain an appropriate plug for the site of the corneal perforation.

The FG-assisted AMT-plug was placed in the perforation area by using FG.

An amniotic membrane patch was placed over the plug, which was then secured by a bandage contact lens.

Result.

Surgery to restore corneal stromal thickness without recurrence of perforation.

Conclusion.

The FG-assisted AMT-plug allowed a successful repair of 1 mm in diameter corneal perforation.

This technique was easily performed, thus seeming to be a good alternative to treat corneal perforations with restoring corneal thickness.

American Psychological Association (APA)

Kara, Selcuk& Arikan, Sedat& Ersan, Ismail& Taskiran Comez, Arzu. 2014. Simplified Technique for Sealing Corneal Perforations Using a Fibrin Glue-Assisted Amniotic Membrane Transplant-Plug. Case Reports in Ophthalmological Medicine،Vol. 2014, no. 2014, pp.1-3.
https://search.emarefa.net/detail/BIM-465028

Modern Language Association (MLA)

Kara, Selcuk…[et al.]. Simplified Technique for Sealing Corneal Perforations Using a Fibrin Glue-Assisted Amniotic Membrane Transplant-Plug. Case Reports in Ophthalmological Medicine No. 2014 (2014), pp.1-3.
https://search.emarefa.net/detail/BIM-465028

American Medical Association (AMA)

Kara, Selcuk& Arikan, Sedat& Ersan, Ismail& Taskiran Comez, Arzu. Simplified Technique for Sealing Corneal Perforations Using a Fibrin Glue-Assisted Amniotic Membrane Transplant-Plug. Case Reports in Ophthalmological Medicine. 2014. Vol. 2014, no. 2014, pp.1-3.
https://search.emarefa.net/detail/BIM-465028

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-465028