Infra-Through Ultrasonic Piezoelectric Acoustic Vector Sensor Particle Rejection System

Joint Authors

Barrett, Ronald M.
Cravens, Scott E.

Source

Smart Materials Research

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-03-29

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Engineering Sciences and Information Technology

Abstract EN

Sensor elements which employ fine filaments are often vulnerable to particulate fouling when used in certain operational field conditions.

Depending on the size, attraction level, thermal and electrical conduction, and charge accumulation properties of the particles, erroneous readings can be easily generated in such “dirty” environments.

This paper describes the design, development, and testing of an ultrasonic system which dynamically rejects highly tenacious electrostatically charged particles of a wide variety of sizes and even water.

The paper starts with a brief introduction to the field of acoustic vector sensing, outlining its outstanding characteristics and history.

Operational challenges including a statistical analysis of typical Middle-Eastern wind-blown desert sand and charge density are laid out.

Several representative subscale hot-wire filaments were fouled with calibrated dust representing desert sand.

The fouled elements were then exposed to airflows of 13 ft/s (4 m/s) and showed highly erratic shifted conduction levels with respect to baseline (clean) levels.

An ultrasonic cleaning system was designed specifically resonate the filament and cantilever so as to mechanically reject foulants.

When operated at resonance, the ultrasonic cleaning system showed 98.6% particulate rejection levels and associated restoration of uncorrupted filament resistance levels to within 2% of baseline resistance measurements.

American Psychological Association (APA)

Cravens, Scott E.& Barrett, Ronald M.. 2012. Infra-Through Ultrasonic Piezoelectric Acoustic Vector Sensor Particle Rejection System. Smart Materials Research،Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-465390

Modern Language Association (MLA)

Cravens, Scott E.& Barrett, Ronald M.. Infra-Through Ultrasonic Piezoelectric Acoustic Vector Sensor Particle Rejection System. Smart Materials Research No. 2012 (2012), pp.1-6.
https://search.emarefa.net/detail/BIM-465390

American Medical Association (AMA)

Cravens, Scott E.& Barrett, Ronald M.. Infra-Through Ultrasonic Piezoelectric Acoustic Vector Sensor Particle Rejection System. Smart Materials Research. 2012. Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-465390

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-465390