Thrombocytopenia in the Setting of Hemodialysis Using Biocompatible Membranes

Joint Authors

Muir, Kathryn B.
Packer, Clifford D.

Source

Case Reports in Medicine

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-4, 4 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-10-09

Country of Publication

Egypt

No. of Pages

4

Main Subjects

Medicine

Abstract EN

Thrombocytopenia is a known potential side effect of hemodialysis, however, it is rarely seen in patients who undergo hemodialysis using biocompatible membranes.

This case demonstrates hemodialysis-associated thrombocytopenia with use of biocompatible dialysis membranes that expose blood directly to polysulfone.

The thrombocytopenia resolved in this patient when the dialysis membrane was changed to a biocompatible model with a polyethylene glycol barrier layer preventing direct interaction between patient blood and polysulfone.

The calculated Naranjo ADR score of 9 indicates a highly probable adverse reaction.

American Psychological Association (APA)

Muir, Kathryn B.& Packer, Clifford D.. 2012. Thrombocytopenia in the Setting of Hemodialysis Using Biocompatible Membranes. Case Reports in Medicine،Vol. 2012, no. 2012, pp.1-4.
https://search.emarefa.net/detail/BIM-465572

Modern Language Association (MLA)

Muir, Kathryn B.& Packer, Clifford D.. Thrombocytopenia in the Setting of Hemodialysis Using Biocompatible Membranes. Case Reports in Medicine No. 2012 (2012), pp.1-4.
https://search.emarefa.net/detail/BIM-465572

American Medical Association (AMA)

Muir, Kathryn B.& Packer, Clifford D.. Thrombocytopenia in the Setting of Hemodialysis Using Biocompatible Membranes. Case Reports in Medicine. 2012. Vol. 2012, no. 2012, pp.1-4.
https://search.emarefa.net/detail/BIM-465572

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-465572