X-Ray Computed Tomography : Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments

Joint Authors

Schmidt, G.
Kietzmann, M.
Mozley, P. D.
Bendtsen, C.
Binnig, G.
Korn, R.

Source

International Journal of Biomedical Imaging

Issue

Vol. 2011, Issue 2011 (31 Dec. 2011), pp.1-11, 11 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2011-05-24

Country of Publication

Egypt

No. of Pages

11

Main Subjects

Medicine

Abstract EN

Background.

This study presents a semiautomated approach for volumetric analysis of lung tumors and evaluates the feasibility of using volumes as an alternative to line lengths as a basis for response evaluation criteria in solid tumors (RECIST).

The overall goal for the implementation was to accurately, precisely, and efficiently enable the analyses of lesions in the lung under the guidance of an operator.

Methods.

An anthropomorphic phantom with embedded model masses and 71 time points in 10 clinical cases with advanced lung cancer was analyzed using a semi-automated workflow.

The implementation was done using the Cognition Network Technology.

Results.

Analysis of the phantom showed an average accuracy of 97%.

The analyses of the clinical cases showed both intra- and interreader variabilities of approximately 5% on average with an upper 95% confidence interval of 14% and 19%, respectively.

Compared to line lengths, the use of volumes clearly shows enhanced sensitivity with respect to determining response to therapy.

Conclusions.

It is feasible to perform volumetric analysis efficiently with high accuracy and low variability, even in patients with late-stage cancer who have complex lesions.

American Psychological Association (APA)

Bendtsen, C.& Kietzmann, M.& Korn, R.& Mozley, P. D.& Schmidt, G.& Binnig, G.. 2011. X-Ray Computed Tomography : Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments. International Journal of Biomedical Imaging،Vol. 2011, no. 2011, pp.1-11.
https://search.emarefa.net/detail/BIM-465909

Modern Language Association (MLA)

Bendtsen, C.…[et al.]. X-Ray Computed Tomography : Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments. International Journal of Biomedical Imaging No. 2011 (2011), pp.1-11.
https://search.emarefa.net/detail/BIM-465909

American Medical Association (AMA)

Bendtsen, C.& Kietzmann, M.& Korn, R.& Mozley, P. D.& Schmidt, G.& Binnig, G.. X-Ray Computed Tomography : Semiautomated Volumetric Analysis of Late-Stage Lung Tumors as a Basis for Response Assessments. International Journal of Biomedical Imaging. 2011. Vol. 2011, no. 2011, pp.1-11.
https://search.emarefa.net/detail/BIM-465909

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-465909