Gastric ESD under Heparin Replacement at High-Risk Patients of Thromboembolism Is Technically Feasible but Has a High Risk of Delayed Bleeding : Osaka University ESD Study Group

Joint Authors

Kitamura, Shinji
Yamaguchi, Shinjiro
Yuguchi, Kiyonori
Yoshio, Toshiyuki
Michida, Tomoki
Komori, Masato
Yabuta, Takamasa
Yamada, Takuya
Kawai, Naoki
Takehara, Tetsuo
Nishida, Tsutomu
Tsujii, Masahiko
Iijima, Hideki
Mita, Eiji
Tsutsui, Shusaku

Source

Gastroenterology Research and Practice

Issue

Vol. 2013, Issue 2013 (31 Dec. 2013), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2013-06-13

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Diseases

Abstract EN

Objectives.

Heparin replacement (HR) is often performed in patients with a high risk of thrombosis undergoing endoscopic procedures.

However, information about the influence of HR is scarce.

The aim of this study is to assess the clinical impact of HR for gastric endoscopic submucosal dissection (ESD).

Methods.

This is a retrospective study comprising approximately 1310 consecutive gastric neoplasms in 1250 patients, who underwent ESD in 5 institutes.

We assessed the clinical findings and outcomes of ESD under HR, compared to ESD without HR as control.

Results.

A total of 24 EGC lesions in 24 patients were treated by ESD under HR.

In the HR group, the complete en-bloc resection rate was 100%.

The delayed bleeding rate was, however, higher in the HR group than in the controls (38% versus 4.6%).

The timing of bleeding in the HR group was significantly later than in controls.

In the control group, 209 patients discontinued antithrombotic therapy during perioperative period, and their delayed bleeding rate was not different from those without antithrombotic therapy (5.7% versus.

4.4%).

A thromboembolic event was encountered in 1 patient under HR after delayed bleeding.

Conclusion.

ESD under HR is technically feasible but has a high risk of delayed bleeding.

American Psychological Association (APA)

Yoshio, Toshiyuki& Nishida, Tsutomu& Kawai, Naoki& Yuguchi, Kiyonori& Yamada, Takuya& Yabuta, Takamasa…[et al.]. 2013. Gastric ESD under Heparin Replacement at High-Risk Patients of Thromboembolism Is Technically Feasible but Has a High Risk of Delayed Bleeding : Osaka University ESD Study Group. Gastroenterology Research and Practice،Vol. 2013, no. 2013, pp.1-7.
https://search.emarefa.net/detail/BIM-466294

Modern Language Association (MLA)

Yoshio, Toshiyuki…[et al.]. Gastric ESD under Heparin Replacement at High-Risk Patients of Thromboembolism Is Technically Feasible but Has a High Risk of Delayed Bleeding : Osaka University ESD Study Group. Gastroenterology Research and Practice No. 2013 (2013), pp.1-7.
https://search.emarefa.net/detail/BIM-466294

American Medical Association (AMA)

Yoshio, Toshiyuki& Nishida, Tsutomu& Kawai, Naoki& Yuguchi, Kiyonori& Yamada, Takuya& Yabuta, Takamasa…[et al.]. Gastric ESD under Heparin Replacement at High-Risk Patients of Thromboembolism Is Technically Feasible but Has a High Risk of Delayed Bleeding : Osaka University ESD Study Group. Gastroenterology Research and Practice. 2013. Vol. 2013, no. 2013, pp.1-7.
https://search.emarefa.net/detail/BIM-466294

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-466294