Iatrogenic Left Main Bronchus Injury following Atraumatic Double Lumen Endotracheal Tube Placement

Joint Authors

Hannon, James
Hartman, William R.
Brown, Michael

Source

Case Reports in Anesthesiology

Issue

Vol. 2013, Issue 2013 (31 Dec. 2013), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2013-10-31

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Medicine

Abstract EN

Tracheobronchial disruption is an uncommon but severe complication of double lumen endotracheal tube placement.

The physical properties of a double lumen tube (large external diameter and length) make tracheobronchial injury more common than that associated with smaller single lumen endotracheal tubes.

Here we present the case of an iatrogenic left main bronchus injury caused by placement of a double lumen tube in an otherwise unremarkable airway.

American Psychological Association (APA)

Hartman, William R.& Brown, Michael& Hannon, James. 2013. Iatrogenic Left Main Bronchus Injury following Atraumatic Double Lumen Endotracheal Tube Placement. Case Reports in Anesthesiology،Vol. 2013, no. 2013, pp.1-3.
https://search.emarefa.net/detail/BIM-478520

Modern Language Association (MLA)

Hartman, William R.…[et al.]. Iatrogenic Left Main Bronchus Injury following Atraumatic Double Lumen Endotracheal Tube Placement. Case Reports in Anesthesiology No. 2013 (2013), pp.1-3.
https://search.emarefa.net/detail/BIM-478520

American Medical Association (AMA)

Hartman, William R.& Brown, Michael& Hannon, James. Iatrogenic Left Main Bronchus Injury following Atraumatic Double Lumen Endotracheal Tube Placement. Case Reports in Anesthesiology. 2013. Vol. 2013, no. 2013, pp.1-3.
https://search.emarefa.net/detail/BIM-478520

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-478520