Optimisation of Radiation Exposure to Gastroenterologists and Patients during Therapeutic ERCP

Joint Authors

Alzimami, Khalid
Theodorou, Kiki
Potamianos, Spiros
Sulieman, Abdelmoneim
Paroutoglou, Georgios
Vlychou, Marianna

Source

Gastroenterology Research and Practice

Issue

Vol. 2013, Issue 2013 (31 Dec. 2013), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2013-03-26

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Diseases

Abstract EN

This study intended to optimize the radiation doses for gastroenterologists and patients during therapeutic endoscopic retrograde cholangiopancreatography (ERCP) and to compare the doses based on available data obtained by other researchers.

A total of 153 patients were studied in two Gastroenterology Departments, (group A, 111; group B, 42).

Thermoluminescent dosimeters (TLD) were used to measure the staff and patients entrance surface air kerma (ESAK) at different body sites.

The mean ESAK and effective doses per procedure were estimated to be 68.75 mGy and 2.74 mSv, respectively.

Staff was exposed to a heterogonous doses.

The third examiner (trainee) was exposed to a high dose compared with other examiners because no shield was located to protect him from stray radiation.

Patients and examiners doses were lower compared to the lowest values found in previous studies taking into consideration the heterogeneity of patients and equipment.

Staff doses during ERCP are within the safety limit in the light of the current practice.

American Psychological Association (APA)

Alzimami, Khalid& Sulieman, Abdelmoneim& Paroutoglou, Georgios& Potamianos, Spiros& Vlychou, Marianna& Theodorou, Kiki. 2013. Optimisation of Radiation Exposure to Gastroenterologists and Patients during Therapeutic ERCP. Gastroenterology Research and Practice،Vol. 2013, no. 2013, pp.1-7.
https://search.emarefa.net/detail/BIM-483061

Modern Language Association (MLA)

Alzimami, Khalid…[et al.]. Optimisation of Radiation Exposure to Gastroenterologists and Patients during Therapeutic ERCP. Gastroenterology Research and Practice No. 2013 (2013), pp.1-7.
https://search.emarefa.net/detail/BIM-483061

American Medical Association (AMA)

Alzimami, Khalid& Sulieman, Abdelmoneim& Paroutoglou, Georgios& Potamianos, Spiros& Vlychou, Marianna& Theodorou, Kiki. Optimisation of Radiation Exposure to Gastroenterologists and Patients during Therapeutic ERCP. Gastroenterology Research and Practice. 2013. Vol. 2013, no. 2013, pp.1-7.
https://search.emarefa.net/detail/BIM-483061

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-483061