Active Comb Filter Using Operational Transconductance Amplifier

Joint Authors

Sorya, Shubham
Yalla, Surya Prasanna
Ranjan, Rajeev Kumar
Paul, Sajal K.

Source

Active and Passive Electronic Components

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-05-22

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Physics

Abstract EN

A new approach for the design of an active comb filter is proposed to remove the selected frequencies of various signals.

The proposed filter is based on only OTAs and capacitors, hence suitable for monolithic integrated circuit implementation.

The workability of the circuit is tested using PSPICE for test signals of 60, 180, 300, and 420 Hz as in ECG signal.

The results are given in the paper and found to agree well with theory.

American Psychological Association (APA)

Ranjan, Rajeev Kumar& Yalla, Surya Prasanna& Sorya, Shubham& Paul, Sajal K.. 2014. Active Comb Filter Using Operational Transconductance Amplifier. Active and Passive Electronic Components،Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-483088

Modern Language Association (MLA)

Ranjan, Rajeev Kumar…[et al.]. Active Comb Filter Using Operational Transconductance Amplifier. Active and Passive Electronic Components No. 2014 (2014), pp.1-6.
https://search.emarefa.net/detail/BIM-483088

American Medical Association (AMA)

Ranjan, Rajeev Kumar& Yalla, Surya Prasanna& Sorya, Shubham& Paul, Sajal K.. Active Comb Filter Using Operational Transconductance Amplifier. Active and Passive Electronic Components. 2014. Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-483088

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-483088