Active Comb Filter Using Operational Transconductance Amplifier
Joint Authors
Sorya, Shubham
Yalla, Surya Prasanna
Ranjan, Rajeev Kumar
Paul, Sajal K.
Source
Active and Passive Electronic Components
Issue
Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-6, 6 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2014-05-22
Country of Publication
Egypt
No. of Pages
6
Main Subjects
Abstract EN
A new approach for the design of an active comb filter is proposed to remove the selected frequencies of various signals.
The proposed filter is based on only OTAs and capacitors, hence suitable for monolithic integrated circuit implementation.
The workability of the circuit is tested using PSPICE for test signals of 60, 180, 300, and 420 Hz as in ECG signal.
The results are given in the paper and found to agree well with theory.
American Psychological Association (APA)
Ranjan, Rajeev Kumar& Yalla, Surya Prasanna& Sorya, Shubham& Paul, Sajal K.. 2014. Active Comb Filter Using Operational Transconductance Amplifier. Active and Passive Electronic Components،Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-483088
Modern Language Association (MLA)
Ranjan, Rajeev Kumar…[et al.]. Active Comb Filter Using Operational Transconductance Amplifier. Active and Passive Electronic Components No. 2014 (2014), pp.1-6.
https://search.emarefa.net/detail/BIM-483088
American Medical Association (AMA)
Ranjan, Rajeev Kumar& Yalla, Surya Prasanna& Sorya, Shubham& Paul, Sajal K.. Active Comb Filter Using Operational Transconductance Amplifier. Active and Passive Electronic Components. 2014. Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-483088
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-483088