Using Optimal Multiple Tuned Liquid Column Dampers for Mitigating the Seismic Response of Structures
Joint Authors
Shakeri, Kazem
Ahadi, Parviz
Mohebbi, Mohtasham
Source
Issue
Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-6, 6 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2012-10-14
Country of Publication
Egypt
No. of Pages
6
Main Subjects
Abstract EN
Tuned liquid column damper (TLCD) has been used extensively to improve the seismic behavior of structures, and different methods have been proposed for optimal design of TLCDs on linear structures.
For improving the effectiveness of TLCDs, multiple tuned liquid column dampers (MTLCDs) have been proposed, and each TLCD has different dynamic parameters.
In this paper designing optimal MTLCDs and assessment of its effectiveness in mitigating the response of structures under earthquake excitations have been studied.
The parameters of TLCDs have been determined based on minimizing the maximum displacement of structure through solving an optimization problem.
Genetic algorithm (GA) has been used for solving the optimization problem.
For illustration, the method has been used for designing optimal MTLCDs for a ten-storey linear shear frame subjected to a white noise excitation.
According to the results of numerical simulations it could be said that the proposed method for designing optimal MTLCDs has been effective regarding the simplicity and convergence behavior of the method.
Based on designing MTLCDs for different values of MTLCDs total mass ratio, it has been concluded that MTLCDs total mass affects significantly the performance of MTMDs where its increasing has led to improve MTLCDs performance.
Also, testing the optimal MTLCDs structure under different testing excitations has shown that the performance of MTLCDs depends on the characteristics of earthquakes.
American Psychological Association (APA)
Ahadi, Parviz& Mohebbi, Mohtasham& Shakeri, Kazem. 2012. Using Optimal Multiple Tuned Liquid Column Dampers for Mitigating the Seismic Response of Structures. ISRN Civil Engineering،Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-483402
Modern Language Association (MLA)
Ahadi, Parviz…[et al.]. Using Optimal Multiple Tuned Liquid Column Dampers for Mitigating the Seismic Response of Structures. ISRN Civil Engineering No. 2012 (2012), pp.1-6.
https://search.emarefa.net/detail/BIM-483402
American Medical Association (AMA)
Ahadi, Parviz& Mohebbi, Mohtasham& Shakeri, Kazem. Using Optimal Multiple Tuned Liquid Column Dampers for Mitigating the Seismic Response of Structures. ISRN Civil Engineering. 2012. Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-483402
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID