Mechanical Models of the Dynamics of Vitreous Substitutes

Joint Authors

Romano, Mario R.
Pralits, Jan O.
Isakova, Krystyna
Repetto, Rodolfo

Source

BioMed Research International

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-10, 10 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-07-24

Country of Publication

Egypt

No. of Pages

10

Main Subjects

Medicine

Abstract EN

We discuss some aspects of the fluid dynamics of vitreous substitutes in the vitreous chamber, focussing on the flow induced by rotations of the eye bulb.

We use simple, yet not trivial, theoretical models to highlight mechanical concepts that are relevant to understand the dynamics of vitreous substitutes and also to identify ideal properties for vitreous replacement fluids.

We first recall results by previous authors, showing that the maximum shear stress on the retina grows with increasing viscosity of the fluid up to a saturation value.

We then investigate how the wall shear stress changes if a thin layer of aqueous humour is present in the vitreous chamber, separating the retina from the vitreous replacement fluid.

The theoretical predictions show that the existence of a thin layer of aqueous is sufficient to substantially decrease the shear stress on the retina.

We finally discuss a theoretical model that predicts the stability conditions of the interface between the aqueous and a vitreous substitute.

We discuss the implications of this model to understand the mechanisms leading to the formation of emulsion in the vitreous chamber, showing that instability of the interface is possible in a range of parameters relevant for the human eye.

American Psychological Association (APA)

Isakova, Krystyna& Pralits, Jan O.& Repetto, Rodolfo& Romano, Mario R.. 2014. Mechanical Models of the Dynamics of Vitreous Substitutes. BioMed Research International،Vol. 2014, no. 2014, pp.1-10.
https://search.emarefa.net/detail/BIM-489341

Modern Language Association (MLA)

Isakova, Krystyna…[et al.]. Mechanical Models of the Dynamics of Vitreous Substitutes. BioMed Research International No. 2014 (2014), pp.1-10.
https://search.emarefa.net/detail/BIM-489341

American Medical Association (AMA)

Isakova, Krystyna& Pralits, Jan O.& Repetto, Rodolfo& Romano, Mario R.. Mechanical Models of the Dynamics of Vitreous Substitutes. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-10.
https://search.emarefa.net/detail/BIM-489341

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-489341