Abstract EN
This paper presents a method of health monitoring for coated steel belts in an elevator system by measuring the electrical resistance of the ropes embedded in the belt.
A model on resistance change caused by fretting wear and stress fatigue has been established.
Temperature and reciprocating cycles are also taken into consideration when determining the potential strength degradation of the belts.
It is proved by experiments that the method could effectively estimate the health degradation of the most dangerous section as well as other ones along the whole belts.
American Psychological Association (APA)
Lei, Huaming& Tian, Guiyun& Zhao, Hui& Mao, Yimei& Huang, Zuoying. 2012. Health Monitoring for Coated Steel Belts in an Elevator System. Journal of Sensors،Vol. 2012, no. 2012, pp.1-5.
https://search.emarefa.net/detail/BIM-495749
Modern Language Association (MLA)
Lei, Huaming…[et al.]. Health Monitoring for Coated Steel Belts in an Elevator System. Journal of Sensors No. 2012 (2012), pp.1-5.
https://search.emarefa.net/detail/BIM-495749
American Medical Association (AMA)
Lei, Huaming& Tian, Guiyun& Zhao, Hui& Mao, Yimei& Huang, Zuoying. Health Monitoring for Coated Steel Belts in an Elevator System. Journal of Sensors. 2012. Vol. 2012, no. 2012, pp.1-5.
https://search.emarefa.net/detail/BIM-495749
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-495749