Considering Angle Selection When Using Ultrasound Electrode Displacement Elastography to Evaluate Radiofrequency Ablation of Tissues

Joint Authors

Zhou, Zhuhuang
Liu, Hao-Li
Tsui, Po-Hsiang
Teng, Jianfu
Xia, Jingjing
Li, Qiang
Wang, Chiao-Yin
Chen, Pin-Yu

Source

BioMed Research International

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-11, 11 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-05-27

Country of Publication

Egypt

No. of Pages

11

Main Subjects

Medicine

Abstract EN

Percutaneous radiofrequency ablation (RFA) is a minimally invasive treatment to thermally destroy tumors.

Ultrasound-based electrode-displacement elastography is an emerging technique for evaluating the region of RFA-induced lesions.

The angle between the imaging probe and the RFA electrode can influence electrode-displacement elastography when visualizing the ablation zone.

We explored the angle effect on electrode-displacement elastography to measure the ablation zone.

Phantoms embedded with meatballs were fabricated and then ablated using an RFA system to simulate RFA-induced lesions.

For each phantom, a commercial ultrasound scanner with a 7.5 MHz linear probe was used to acquire raw image data at different angles, ranging from 30° to 90° at increments of 10°, to construct electrode-displacement images and facilitate comparisons with tissue section images.

The results revealed that the ablation regions detected using electrode-displacement elastography were highly correlated with those from tissue section images when the angle was between 30° and 60°.

However, the boundaries of lesions were difficult to distinguish, when the angle was larger than 60°.

The experimental findings suggest that angle selection should be considered to achieve reliable electrode-displacement elastography to describe ablation zones.

American Psychological Association (APA)

Xia, Jingjing& Li, Qiang& Chen, Pin-Yu& Zhou, Zhuhuang& Wang, Chiao-Yin& Liu, Hao-Li…[et al.]. 2014. Considering Angle Selection When Using Ultrasound Electrode Displacement Elastography to Evaluate Radiofrequency Ablation of Tissues. BioMed Research International،Vol. 2014, no. 2014, pp.1-11.
https://search.emarefa.net/detail/BIM-496973

Modern Language Association (MLA)

Xia, Jingjing…[et al.]. Considering Angle Selection When Using Ultrasound Electrode Displacement Elastography to Evaluate Radiofrequency Ablation of Tissues. BioMed Research International No. 2014 (2014), pp.1-11.
https://search.emarefa.net/detail/BIM-496973

American Medical Association (AMA)

Xia, Jingjing& Li, Qiang& Chen, Pin-Yu& Zhou, Zhuhuang& Wang, Chiao-Yin& Liu, Hao-Li…[et al.]. Considering Angle Selection When Using Ultrasound Electrode Displacement Elastography to Evaluate Radiofrequency Ablation of Tissues. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-11.
https://search.emarefa.net/detail/BIM-496973

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-496973