Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla

Joint Authors

Gerstenblith, Gary
Kelle, Sebastian
Weiss, Robert G.
Schlendorf, Kelly
Stuber, Matthias
Hirsch, Glenn A.
Fleck, Eckart

Source

Cardiology Research and Practice

Issue

Vol. 2010, Issue 2010 (31 Dec. 2010), pp.1-9, 9 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2010-10-11

Country of Publication

Egypt

No. of Pages

9

Main Subjects

Diseases

Abstract EN

Purpose.

We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD).

Materials and Methods.

Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61±10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands).

T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA).

Results.

LGE was seen in none of the healthy subjects, however in all of the CAD patients.

In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast.

At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced.

Conclusion.

In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects.

In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30–45 minutes after administration of the contrast agent.

American Psychological Association (APA)

Kelle, Sebastian& Schlendorf, Kelly& Hirsch, Glenn A.& Gerstenblith, Gary& Fleck, Eckart& Weiss, Robert G.…[et al.]. 2010. Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla. Cardiology Research and Practice،Vol. 2010, no. 2010, pp.1-9.
https://search.emarefa.net/detail/BIM-503732

Modern Language Association (MLA)

Kelle, Sebastian…[et al.]. Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla. Cardiology Research and Practice No. 2010 (2010), pp.1-9.
https://search.emarefa.net/detail/BIM-503732

American Medical Association (AMA)

Kelle, Sebastian& Schlendorf, Kelly& Hirsch, Glenn A.& Gerstenblith, Gary& Fleck, Eckart& Weiss, Robert G.…[et al.]. Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla. Cardiology Research and Practice. 2010. Vol. 2010, no. 2010, pp.1-9.
https://search.emarefa.net/detail/BIM-503732

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-503732