Abstract EN
Purpose.
We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD).
Materials and Methods.
Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61±10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands).
T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA).
Results.
LGE was seen in none of the healthy subjects, however in all of the CAD patients.
In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast.
At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced.
Conclusion.
In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects.
In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30–45 minutes after administration of the contrast agent.
American Psychological Association (APA)
Kelle, Sebastian& Schlendorf, Kelly& Hirsch, Glenn A.& Gerstenblith, Gary& Fleck, Eckart& Weiss, Robert G.…[et al.]. 2010. Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla. Cardiology Research and Practice،Vol. 2010, no. 2010, pp.1-9.
https://search.emarefa.net/detail/BIM-503732
Modern Language Association (MLA)
Kelle, Sebastian…[et al.]. Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla. Cardiology Research and Practice No. 2010 (2010), pp.1-9.
https://search.emarefa.net/detail/BIM-503732
American Medical Association (AMA)
Kelle, Sebastian& Schlendorf, Kelly& Hirsch, Glenn A.& Gerstenblith, Gary& Fleck, Eckart& Weiss, Robert G.…[et al.]. Gadolinium Enhanced MR Coronary Vessel Wall Imaging at 3.0 Tesla. Cardiology Research and Practice. 2010. Vol. 2010, no. 2010, pp.1-9.
https://search.emarefa.net/detail/BIM-503732
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-503732