Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals

Joint Authors

Montenegro, M. C. B. S. M.
Santos, Lúcia H. M. L. M.
Reis, Boaventura F.
Araújo, A. N.

Source

Journal of Automated Methods and Management in Chemistry

Issue

Vol. 2010, Issue 2010 (31 Dec. 2010), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2010-10-13

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Chemistry

Abstract EN

A new flow procedure based on multicommutation with chemiluminometric detection was developed to quantify gentamicin sulphate in pharmaceutical formulations.

This approach is based on gentamicin's ability to inhibit the chemiluminometric reaction between luminol and hypochlorite in alkaline medium, causing a decrease in the analytical signal.

The inhibition of the analytical signal is proportional to the concentration of gentamicin sulphate, within a linear range of 1 to 4 μg mL-1 with a coefficient variation <3%.

A sample throughput of 55 samples h-1 was obtained.

The developed method is sensitive, simple, with low reagent consumption, reproducible, and inexpensive, and when applied to the analysis of pharmaceutical formulations (eye drops and injections) it gave results with RSD between 1.10 and 4.40%.

American Psychological Association (APA)

Santos, Lúcia H. M. L. M.& Araújo, A. N.& Reis, Boaventura F.& Montenegro, M. C. B. S. M.. 2010. Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals. Journal of Automated Methods and Management in Chemistry،Vol. 2010, no. 2010, pp.1-7.
https://search.emarefa.net/detail/BIM-507572

Modern Language Association (MLA)

Santos, Lúcia H. M. L. M.…[et al.]. Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals. Journal of Automated Methods and Management in Chemistry No. 2010 (2010), pp.1-7.
https://search.emarefa.net/detail/BIM-507572

American Medical Association (AMA)

Santos, Lúcia H. M. L. M.& Araújo, A. N.& Reis, Boaventura F.& Montenegro, M. C. B. S. M.. Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals. Journal of Automated Methods and Management in Chemistry. 2010. Vol. 2010, no. 2010, pp.1-7.
https://search.emarefa.net/detail/BIM-507572

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-507572