Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments

Joint Authors

Schiel, Ralf
Bambauer, Rolf
Latza, Reinhard
Bambauer, Carolin

Source

International Journal of Nephrology

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-8, 8 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-04-10

Country of Publication

Egypt

No. of Pages

8

Main Subjects

Diseases
Medicine

Abstract EN

Background.

Catheter-related infections, thrombosis, and stenosis are among the most frequent complications associated with catheters, which are inserted in vessels.

Surface treatment processes of the outer surface, such as ion-beam-assisted deposition, can be used to mitigate such complications.

Methods.

This retrospective study (1992–2007) evaluated silver-coated (54 patients) and noncoated (105 patients) implanted large-bore catheters used for extracorporeal detoxification.

The catheters were inserted into the internal jugular or subclavian veins.

After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays.

They also were examined using scanning electron microscope.

Results.

The silver coated catheters showed a tendency towards longer in situ time.

The microbiologic examinations of the catheter tips were in both catheter types high positive, but not significant.

Conclusion.

The silver-coated catheters showed no significantly reduction in infection rate by evaluation of all collected data in this retrospective study.

There was no association between both catheters in significantly reducing savings in treatment costs and in reducing patient discomfort.

Other new developed catheter materials such as the microdomain-structured inner and outer surface are considered more biocompatible because they mimic the structure of natural biological surface.

American Psychological Association (APA)

Bambauer, Rolf& Schiel, Ralf& Bambauer, Carolin& Latza, Reinhard. 2012. Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments. International Journal of Nephrology،Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-511213

Modern Language Association (MLA)

Bambauer, Rolf…[et al.]. Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments. International Journal of Nephrology No. 2012 (2012), pp.1-8.
https://search.emarefa.net/detail/BIM-511213

American Medical Association (AMA)

Bambauer, Rolf& Schiel, Ralf& Bambauer, Carolin& Latza, Reinhard. Surface-Treated versus Untreated Large-Bore Catheters as Vascular Access in Hemodialysis and Apheresis Treatments. International Journal of Nephrology. 2012. Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-511213

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-511213