New mode for the on-line determination of amiloride in pure and pharmaceutical preparation using CFIA via the use of linear array from six led (snow white)‎ with one solar cell in a homemade ayah 6sx1-T-1d solar CFI analyser

Other Title(s)

نمط جديد للتقدير الآني للاميلورايد في المستحضرات الصيدلانية و النقية باستخدام التحليل بالحقن الجرياني المستمر عن طريق مصفوفة خطية ل ست ثنائي وصلة باعث للضوء الأبيض الثلجي مع خلية شمسية في محلل لقياس التعكرية Ayah 6Sx1-T-1D solar CFI

Author

al-Hashimi, Isam Muhammad Ali Shakir

Source

Iraqi Journal of Science

Issue

Vol. 55, Issue 4B (31 Dec. 2014), pp.1708-1720, 13 p.

Publisher

University of Baghdad College of Science

Publication Date

2014-12-31

Country of Publication

Iraq

No. of Pages

13

Main Subjects

Chemistry

Topics

Abstract AR

طورت طريقة جديدة بالحقن الجرياني لقياس التعكرية و تميزت بالسرعة و الحساسية لتقدير الأميلورايد في المستحضرات الصيدلانية و النقية.

استندت على تكوين راسب أبيض مصفر للمزدوج الأيوني : أميلورايد – حامض موليبدات الفسفوريك في الوسط المائي.

تم قياس التعكرية بوساطة محلل الحقن الجرياني المستمر Ayah 6Sx1 – T – 1D solar cells-CFI analyzer عن طريق توهين الضوء المسلط من على سطوح دقائق الراسب بزاوية °180 – 0.

تم دراسة الظروف الفضلى من المتغيرات الفيزيائية و الكيميائية.

المدى الخطي الفعال لعلاقة توهين الضوء الساقط ضد تركيز الأميلورايد 10 – 0.005 مللي مول.لتر1- مع معامل ارتباط (r) : 0.9986 و نسبة الخطية % 99.71 = (r2%).

معامل التقدير الكمي (L.O.Q) : 23.14 مكغم/انموذج بينما حد الكشف 5.74 (S/N = 3) L.O.D نانوغرام/انموذج من التخفيف التدريجي لأقل تركيز في منحني المعايرة.

الإنحراف القياسي النسبي المئوي لتركيز 3 و 9 مللي مول.لتر1- من الأميلورايد أقل من 0.5 % (تكرارية لثمان مرات) باستخدام حجم لأنموذج محقن 50 مايكرولتر.

معدل النمذجة 40 أنموذج/ساعة.

طبقت الطريقة بنجاح لتقدير الأميلورايد في المستحضرات الصيدلانية.

أجريت مقارنة باستخدام منحني الإضافات القياسية و اختبار t- المزدوج و لوحظ عدم وجود فرق جوهري بين القيمة الرسمية للإختبارات الإنفرادية و قيمة t- المحسوبة عند فاصل ثقة % 95 للطريقة المطورة بالإضافة إلى إجراء مقارنة بين الطريقتين و لوحظ عدم وجود فرق جوهري بينمها عند 0.05 = α (مستوى الثقة % 95).

Abstract EN

A newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations.

It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium.

Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180°.

The Chemical and physical parameters were investigated.

Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986, while the percentage linearity (r2 %) was 99.71 %.

The L.O.Q was of 23.14 μg / sample, while L.O.D (S / N = 3) = 5.74 ng / sample from the stepwise dilution for the minimum concentration in the calibration graph.

The R.S.D % at 3, 9 mmol.L-1 Amiloride is less than 0.5 % (eight replicates) using 50 μL sample volume.

Through put was of 40 sample.hr-1.

The method was applied successfully for the determination of Amiloride in pharmaceutical preparations.

A comparison was made using the standard additions method via the use paired t-test.

It showed that there was no significant difference between the quoted value of each individual paired t-test with calculated t-value at 95 % confidence interval from developed method.

In addition to comparison between two methods and calculate t-value, it was noticed that there was no significant difference between the two methods at ∝ = 0.05 (95 % confidence level).

American Psychological Association (APA)

al-Hashimi, Isam Muhammad Ali Shakir. 2014. New mode for the on-line determination of amiloride in pure and pharmaceutical preparation using CFIA via the use of linear array from six led (snow white) with one solar cell in a homemade ayah 6sx1-T-1d solar CFI analyser. Iraqi Journal of Science،Vol. 55, no. 4B, pp.1708-1720.
https://search.emarefa.net/detail/BIM-526975

Modern Language Association (MLA)

al-Hashimi, Isam Muhammad Ali Shakir. New mode for the on-line determination of amiloride in pure and pharmaceutical preparation using CFIA via the use of linear array from six led (snow white) with one solar cell in a homemade ayah 6sx1-T-1d solar CFI analyser. Iraqi Journal of Science Vol. 55, no. 4B (2014), pp.1708-1720.
https://search.emarefa.net/detail/BIM-526975

American Medical Association (AMA)

al-Hashimi, Isam Muhammad Ali Shakir. New mode for the on-line determination of amiloride in pure and pharmaceutical preparation using CFIA via the use of linear array from six led (snow white) with one solar cell in a homemade ayah 6sx1-T-1d solar CFI analyser. Iraqi Journal of Science. 2014. Vol. 55, no. 4B, pp.1708-1720.
https://search.emarefa.net/detail/BIM-526975

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 1720

Record ID

BIM-526975