Pregnancy detection in rabbits by ultrasonography as compared to manual palpation

Other Title(s)

تشخيص الحمل في الأرنب باستخدام الموجات فوق الصوتية المصورة و مقارنتها بالجس البطني

Joint Authors

ai-Juiar, Mutazz
Hanafi, Ahmad
Yasin, Muhammad Ahmad
Hijazi, al-Sayyid
Marthold, Danil
Gauly, Matuas
Holtz, Walfajanj
Khalil, Hasan Abd al-Ghaffar

Source

Egyptian Journal of Animal Production

Issue

Vol. 51, Issue 3 (30 Sep. 2014), pp.196-199, 4 p.

Publisher

Egyptian Society of Animal Production

Publication Date

2014-09-30

Country of Publication

Egypt

No. of Pages

4

Main Subjects

Veterinary Medicine

Topics

Abstract AR

الهدف من البحث : الجس البطني هو أكثر الطرق المستخدمة شيوعا في تشخيص الحمل في الأرانب.

كما تعتبر الموجات فوق الصوتية المصورة من أهم التقنيات الحديثة المستخدمة في تشخيص الحمل المبكر في الحيوانات المزرعية.

و نظراً لندرة المعلومات المتاحة عن إمكانية و دقة استخدام هذه التقنية لتشخيص الحمل في الأرانب، كان الهدف من هذه الدراسة هو شخيص الحمل في أمهات الأرانب النيوزيلاندي باستخدام تقنية الموجات فوق الصوتية المصورة باطنياً و مقارنتها بالجس البطني اليدوي.

الأجهزة و الطرق المستخدمة في البحث : تم تشخيص الحمل في أمهات الأرانب النيوزيلاندي (28 أم) باستخدام جهاز الموجات فوق الصوتية المصورة (بماسح باطني قدرة ٥ ميغا هرتز)، و كذا بطريقة الجس البطني اليدوي، يومياً بداية من اليوم الخامس من الحمل و إلى أن يتم تشخيص الحمل بشكل مؤكد.

أهم النتائج و الاستنتاجات المستخرجة من البحث : أظهرت متوسطات النتائج أن السوائل الرحمية أمكن تميزها من اليوم 6.2 ± 0.2 من الحمل، و كذلك فإن دقات القلب الجنينية أمكن تميزها من اليوم 7.8 ± 0.1 من الحمل.

بينما شخص الحمل بطريقة الجس البطني اليدوي بشكل مؤكد عند اليوم 10.9 ± 0.3 من الحمل.

أما فيما يتعلق بدقة تشخيص الحمل باستخدام الموجات فوق الصوتية المصورة أو الجس البطني فقد كانت 100 %.

لم تسجل أي حالات إجهاض في الأمهات كما لوحظ عدم وجود أي شواذ في أي من الأجنة الناتجة.

و يستنتج من هذه الدراسة أن طريقة تشخيص الحمل في الأرانب بالموجات فوق الصوتية تعد طريقة آمنة و سريعة و عملية و دقيقة مما يعني الوثوق فيها لتشخيص الحمل المبكر في الأرانب.

Abstract EN

The most common way of detecting pregnancy in rabbits is by manual palpation.

Real-time ultrasonography may be an alternative to be used in rabbit production units in the future if it turns out to be practicable.

There is a paucity of scientific knowledge on the suitability of real-time ultrasonography for pregnancy diagnosis in rabbits.

In the present study pregnancy diagnosis by transabdominal ultrasonography was compared to manual abdominal palpation in 28 mated New Zealand rabbit does.

Ultrasonography with the aid of a real-time scanner, equipped with five MHz linear-array transducer and manual palpation were executed by one individual daily, beginning at day five after mating.

For ultrasound scanning, does were restrained in a dorsal recumbent position and, to establish firm skin contact, gel was applied to the clipped caudal abdomen.

Manual abdominal palpation provided a reliable diagnosis by day 10.

9 ± 0.

3.

By ultrasonography, uterine fluid was detected 6.2 ± 0.

2 days after mating; fetal heartbeat by day 7.

8 ± 0.

1.

In the 20 does that went to term (71 %), the reliability of both ultrasonic pregnancy detection (based on the observation of heart beat) and manual palpation was 100 %.

No abortions or stillborn kits were recorded and the kits born were normal and viable.

In conclusion, real-time ultrasonography, being accurate, rapid and safe, may be considered as a viable alternative for other means of early pregnancy diagnosis in rabbits.

American Psychological Association (APA)

ai-Juiar, Mutazz& Khalil, Hasan Abd al-Ghaffar& Hanafi, Ahmad& Yasin, Muhammad Ahmad& Hijazi, al-Sayyid& Marthold, Danil…[et al.]. 2014. Pregnancy detection in rabbits by ultrasonography as compared to manual palpation. Egyptian Journal of Animal Production،Vol. 51, no. 3, pp.196-199.
https://search.emarefa.net/detail/BIM-563067

Modern Language Association (MLA)

ai-Juiar, Mutazz…[et al.]. Pregnancy detection in rabbits by ultrasonography as compared to manual palpation. Egyptian Journal of Animal Production Vol. 51, no. 3 (Sep. 2014), pp.196-199.
https://search.emarefa.net/detail/BIM-563067

American Medical Association (AMA)

ai-Juiar, Mutazz& Khalil, Hasan Abd al-Ghaffar& Hanafi, Ahmad& Yasin, Muhammad Ahmad& Hijazi, al-Sayyid& Marthold, Danil…[et al.]. Pregnancy detection in rabbits by ultrasonography as compared to manual palpation. Egyptian Journal of Animal Production. 2014. Vol. 51, no. 3, pp.196-199.
https://search.emarefa.net/detail/BIM-563067

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 198

Record ID

BIM-563067