Assessment of plasma Cystatin C among Sudanese patients with type II

Other Title(s)

تقييم (Cystatin C)‎ البلازما بين المرضى السودانيين من النوع الثانيمن مرضى السكري

Joint Authors

Ahmad, Non Babakr Muhammad
al-Ubayd, Badr al-Din Hasan
Sadiq, Isam Ahmad Muhammad
Abd al-Hamid, Muhammad
Ahmad, Samiyah Mahdi

Source

Sudan Journal of Medical Sciences

Issue

Vol. 9, Issue 1 (31 Mar. 2014), pp.39-42, 4 p.

Publisher

Omdurman Islamic University Faculty of Medicine

Publication Date

2014-03-31

Country of Publication

Sudan

No. of Pages

4

Main Subjects

Medicine

Topics

Abstract AR

خلفية : يستخدم (Cystatin C) أساسا كعلامة بيولوجية لوظائف الكلى.

يتم تصفيته بحرية من قبل كبيبات الكلى، و لا يعود إلى مجرى الدم أو يفرز من الأنابيب الكلوية.

و قد اقترح أن يكون أقرب إلى " مثالية " علامة الذاتية.

الأهداف : تقييم مستويات البلازما من (cystatin (Cystatin C ج، تصفية الكرياتينين، نسبة HbA1c % الدم و مؤشر كتلة الجسم بين السودانيين مع نوع 2 من داء السكري.

المواد و الطرق : هذه دراسة الحالات و الشواهد التي أجريت في مراكز السكري في ولاية الخرطوم، السودان، في الفترة من مارس 2010 إلى نوفمبر 2013.

تم تسجيل ما مجموعه 300 من المرضى السودانيين المصابين بداء السكري (49 % ذكور و 51 % إناث) كمجموعة دراسة، و 150 شخصا سليما ( 48 % ذكور و 52 % إناث) كمجموعة تحكم في هذه الدراسة.

و يقابل كلا الفريقين لنوع الجنس و السن.

تم قياس مستويات البلازما من (Cystatin C)، الكرياتينين و نسبة (HbA1c) الدم باستخدام تقنية نيفيلوميتري و حساب تصفية الكرياتينين لكل مشارك.

تم الخدام البرنامج الإحصائي (SPSS) لتحليل البيانات.

النتائج : متوسطات مستويات البلازما من (Cystatin C)، نسبة ( HbA1c %) و مؤشر كتلة الجسم (BMI) كانت بشكل كبير في مجموعة مرضى السكري مقارنة مع مجموعة التحكم (0.05 > P) و كانت هناك علاقة سلبية ذات دلالة إحصائية معتدلة بين (Cystatin C) و.

تصفية الكرياتينين (0.69 = r، 0.015 = P) في مجموعة السكري، و هناك علاقة إيجابية قوية ذات دلالة إحصائية بين مستويات البلازما من (Cystatin C) و نسبة (% HbAlc) (0.78 = r، 0.044 = P).

الاستنتاج : تشير البيانات الحالية من المرضى السودانيين مع النوع الثاني من مرض السكري، إلى زيادة كبيرة في مستويات البلازما من (Cystatin C) و لها ارتباط إيجابي قوي كبير مع HbA1c و إلى وجود علاقة طبية كبيرة معتدلة مع تصفية الكرياتينين.

Abstract EN

Cystatin C is mainly used as a biomarker of kidney function.

It is freely filtered by glomerulus, and does not return to the blood stream or secreted by renal tubules.

It has been suggested to be closer to the “ideal” endogenous marker.

Objectives : To assess the plasma levels of cystatin c, creatinine clearance, blood HbA1C % and body mass index among Sudanese with type 2 Diabetes.

Materials and methods : This is a case-control study conducted in diabetic centers in Khartoum state, Sudan, from March 2010 to November 2013.

A total of 300 Sudanese patients with type2 diabetes (49 % males and 51% females) as a test group, and 150 healthy subjects (48 %males and 52 % females) as a control group were enrolled in this study.

Both groups were matched for gender and age.

The plasma levels of Cystatin C, creatinine and blood HbA1c were measured using Nephelometry technique.

Creatinine clearance was calculated for each participant.

SPSS was used for analysis of data.

Results : The means of the plasma levels of Cystatin C, HbA1c % and the body mass index (BMI) were significantly raised in the diabetic group compared to the control group (p < 0.

05).There is significant moderate negative correlation between Cystatin C and creatinine clearance (r = 0.

69, p = 0.

015) in the diabetic group, and there is a significant strong positive correlation between the plasma levels of Cystatin C and HbA1c %(r = o.

78, p = 0.

044).

Conclusion: The present data indicates that among Sudanese patients with Type 2 Diabetes Mellitus, plasma levels of Cystatin C are significantly raised and has a significant strong positive correlation with glycated haemoglobin % and a significant moderate negative correlation with creatinine clearance.

American Psychological Association (APA)

Ahmad, Non Babakr Muhammad& al-Ubayd, Badr al-Din Hasan& Ahmad, Samiyah Mahdi& Sadiq, Isam Ahmad Muhammad& Abd al-Hamid, Muhammad. 2014. Assessment of plasma Cystatin C among Sudanese patients with type II. Sudan Journal of Medical Sciences،Vol. 9, no. 1, pp.39-42.
https://search.emarefa.net/detail/BIM-565847

Modern Language Association (MLA)

Ahmad, Non Babakr Muhammad…[et al.]. Assessment of plasma Cystatin C among Sudanese patients with type II. Sudan Journal of Medical Sciences Vol. 9, no. 1 (Mar. 2014), pp.39-42.
https://search.emarefa.net/detail/BIM-565847

American Medical Association (AMA)

Ahmad, Non Babakr Muhammad& al-Ubayd, Badr al-Din Hasan& Ahmad, Samiyah Mahdi& Sadiq, Isam Ahmad Muhammad& Abd al-Hamid, Muhammad. Assessment of plasma Cystatin C among Sudanese patients with type II. Sudan Journal of Medical Sciences. 2014. Vol. 9, no. 1, pp.39-42.
https://search.emarefa.net/detail/BIM-565847

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references : p. 42

Record ID

BIM-565847